Simultaneous liquid chromatographic determination of ezetimibe and simvastatin in pharmaceutical products
- PMID: 18193733
Simultaneous liquid chromatographic determination of ezetimibe and simvastatin in pharmaceutical products
Abstract
A reversed-phase liquid chromatographic (LC) method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical dosage forms. The LC method was carried out on a Synergi fusion C18 column (150 mm x 4.6 mm id) maintained at 45 degrees C. The mobile phase consisted of phosphate buffer 0.03 M, pH 4.5-acetonitrile (35 + 65, v/v) run at a flow rate of 0.6 mL/min, and detection was made using a photodiode array detector at 234 nm. The chromatographic separation was obtained within 15.0 min, and calibration graphs were linear in the concentration range of 0.5-200 microg/mL. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated, giving results within the acceptable range for both compounds. Moreover, the proposed method was successfully applied for the routine quality control analysis of pharmaceutical products.
Similar articles
-
Stability-indicating reversed-phase liquid chromatographic method for simultaneous determination of atorvastatin and ezetimibe from their combination drug products.J AOAC Int. 2007 Nov-Dec;90(6):1539-46. J AOAC Int. 2007. PMID: 18193730
-
Rapid and sensitive simultaneous determination of ezetimibe and simvastatin from their combination drug products by monolithic silica high-performance liquid chromatographic column.J Pharm Biomed Anal. 2009 Oct 15;50(3):527-34. doi: 10.1016/j.jpba.2009.05.002. Epub 2009 May 13. J Pharm Biomed Anal. 2009. PMID: 19487095
-
Development and validation of spectrophotometeric method for simultaneous determination of simvastatin and ezetimibe in tablet formulations.Pak J Pharm Sci. 2010 Oct;23(4):375-8. Pak J Pharm Sci. 2010. PMID: 20884449
-
Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC.J Chromatogr Sci. 2010 Feb;48(2):95-9. doi: 10.1093/chromsci/48.2.95. J Chromatogr Sci. 2010. PMID: 20109284
-
Analysis of five HMG-CoA reductase inhibitors-- atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin: pharmacological, pharmacokinetic and analytical overview and development of a new method for use in pharmaceutical formulations analysis and in vitro metabolism studies.Biomed Chromatogr. 2006 Mar;20(3):282-93. doi: 10.1002/bmc.561. Biomed Chromatogr. 2006. PMID: 16143964 Review.
Cited by
-
A Fast and Validated Reversed-Phase HPLC Method for Simultaneous Determination of Simvastatin, Atorvastatin, Telmisartan and Irbesartan in Bulk Drugs and Tablet Formulations.Sci Pharm. 2017 Dec 19;86(1):1. doi: 10.3390/scipharm86010001. Sci Pharm. 2017. PMID: 29257120 Free PMC article.
-
Microemulsion liquid chromatographic method for simultaneous determination of simvastatin and ezetimibe in their combined dosage forms.J Anal Methods Chem. 2013;2013:132836. doi: 10.1155/2013/132836. Epub 2013 Oct 27. J Anal Methods Chem. 2013. PMID: 24282651 Free PMC article.
-
Development of a sustainable multianalyte MEKC method for quantitation of the antihyperlipidemic drugs ezetimibe together with three statins. Greenness and whiteness appraisal studies.BMC Chem. 2023 Sep 23;17(1):124. doi: 10.1186/s13065-023-01040-y. BMC Chem. 2023. PMID: 37742031 Free PMC article.
-
Micelle-enhanced spectrofluorimetric method for determination of cholesterol-reducing drug ezetimibe in dosage forms.J Fluoresc. 2012 Jan;22(1):9-15. doi: 10.1007/s10895-011-0952-x. Epub 2011 Aug 23. J Fluoresc. 2012. PMID: 21858740
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical