Multicenter Study
. 2008 Apr;246(4):587-92.
doi: 10.1007/s00417-007-0760-9. Epub 2008 Jan 12.

Central corneal thickness in adult Chinese. Association with ocular and general parameters. The Beijing Eye Study

Affiliations
Multicenter Study

Central corneal thickness in adult Chinese. Association with ocular and general parameters. The Beijing Eye Study

Haitao Zhang et al. Graefes Arch Clin Exp Ophthalmol. 2008 Apr.

Abstract

Background: To evaluate the distribution of central corneal thickness and its associations in the adult Chinese population.

Methods: The Beijing Eye Study 2006 is a population-based study including 3,251 (73.3%) subjects (aged 45+ years) out of 4,439 subjects who participated in the survey in 2001 and who returned for re-examination. Central corneal thickness (CCT) measurements were performed by slit lamp-based optical coherence tomography.

Results: Central corneal thickness measurement data were available for 3,100 (95.4%) subjects. Mean CCT was 556.2+/-33.1 microm (median: 553 microm; range: 429-688 microm). In multiple regression analysis, CCT was significantly associated with optic disc area (P = 0.043), urban region (P < 0.001; odds ratio (OR): 4.77; 95% confidence interval (CI): 2.37, 7.17), male gender (P < 0.001; OR: 5.64; 95%CI: 2.57, 8.71), and intraocular pressure measurements (P < 0.001). It was not significantly associated with body weight (P = 0.54) and body height (P = 0.66), age (P = 0.17), and refractive error (P = 0.43). Intraocular pressure (measured by pneumotonometry) increased for each microm central corneal thickness increase by 0.03 mmHg.

Conclusions: In the adult Chinese population, CCT was significantly associated optic disc area, urban region, and male gender. Intraocular pneumotonometric pressure measurements increased for each microm increase in central corneal thickness by 0.03 mmHg. CCT was not associated with age and refractive error.

PubMed Disclaimer

References

    1. Klin Monbl Augenheilkd. 2000 Oct;217(4):219-24 - PubMed
    1. Ophthalmology. 2005 Feb;112(2):251-6 - PubMed
    1. Surv Ophthalmol. 2000 Mar-Apr;44(5):367-408 - PubMed
    1. Am J Ophthalmol. 2006 Jun;141(6):1078-1086 - PubMed
    1. Acta Ophthalmol Scand. 2002 Feb;80(1):11-5 - PubMed

Publication types

LinkOut - more resources