Alumina-on-alumina in THA: a multicenter prospective study
- PMID: 18196411
- PMCID: PMC2505151
- DOI: 10.1007/s11999-007-0042-1
Alumina-on-alumina in THA: a multicenter prospective study
Abstract
Different bearing surfaces, including alumina-on-alumina, have been used to avoid osteolysis. We prospectively followed 288 patients (319 hips) in which an alumina-on-alumina cup was used with a hydroxyapatite stem. The patients' mean age was 52.7 (range, 14-70 years), and the minimum followup was 3 years (mean, 4.7 years; range, 3-8 years). At final followup, five cups (including one with an alumina liner fracture) and two stems underwent revision. The cumulative probability of not having a revision of one or both components for any cause was 97% (95% confidence interval, 94.7%-99.1%). No patient spontaneously reported any noises from the hip and none reported noises when specifically questioned. All patients who had not undergone revision had good clinical results, but five of these patients had radiographic cup loosening at last followup. These data suggest alumina-on-alumina prostheses had reasonable outcomes after 5 years. One acetabular component fractured from trauma. We observed no linear femoral head penetration. Continued followup will be required to determine if reduction in wear between the alumina-on-alumina bearings results in less osteolysis and loosening.
Level of evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Figures
References
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'PubMed', 'value': '28224596', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/28224596/'}]}
- Bal BS, Aleto TJ, Garino JP, Toni A, Hendricks KJ. Ceramic-on ceramic versus ceramic-on-polyethylene bearings in total hip arthroplasty: results of a multicenter prospective randomized study and update of modern ceramic total hip trials in the United States. Hip International. 2005;15:129–135. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1302/0301-620X.86B2.14026', 'is_inner': False, 'url': 'https://doi.org/10.1302/0301-620x.86b2.14026'}, {'type': 'PubMed', 'value': '15046431', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/15046431/'}]}
- Bizot P, Hannouche D, Nizard R, Witvoet J, Sedel L. Hybrid alumina total hip arthroplasty using press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation. J Bone Joint Surg Br. 2004;86:190–194. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1097/00003086-200112000-00010', 'is_inner': False, 'url': 'https://doi.org/10.1097/00003086-200112000-00010'}, {'type': 'PubMed', 'value': '11764375', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/11764375/'}]}
- Bizot P, Nizard R, Hamadouche M, Hannouche D, Sedel L. Prevention of wear and osteolysis. Alumina-on-alumina bearing. Clin Orthop Relat Res. 2001;393:85–93. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1016/S0883-5403(99)90062-1', 'is_inner': False, 'url': 'https://doi.org/10.1016/s0883-5403(99)90062-1'}, {'type': 'PubMed', 'value': '10220190', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/10220190/'}]}
- Bobyn JD, Toh KK, Hacking SA, Tanzer M, Krygier JJ. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty. 1999;14:347–354. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1097/00003086-200010000-00002', 'is_inner': False, 'url': 'https://doi.org/10.1097/00003086-200010000-00002'}, {'type': 'PubMed', 'value': '11039786', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/11039786/'}]}
- Boutin P. Total hip arthroplasty using a ceramic prosthesis. The Classic. Clin Orthop Relat Res. 2000;379:3–11. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials