Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2008 Jan-Feb;4(1):55-9.
doi: 10.1016/j.soard.2007.07.012.

First human experience with endoscopically delivered and retrieved duodenal-jejunal bypass sleeve

Affiliations
Clinical Trial

First human experience with endoscopically delivered and retrieved duodenal-jejunal bypass sleeve

Leonardo Rodriguez-Grunert et al. Surg Obes Relat Dis. 2008 Jan-Feb.

Abstract

Background: We report the first human experience with an endoscopic duodenal-jejunal bypass sleeve (DJBS) in a community hospital.

Methods: The DJBS is a 60-cm sleeve anchored in the duodenum to create a duodenal-jejunal bypass. In a 12-patient prospective, open-label, single-center, 12-week study, the device was endoscopically implanted, left in situ, and retrieved. The study included 5 men and 7 women, with a mean body mass index of 43 kg/m(2). Of the 12 patients, 4 had type 2 diabetes. The primary endpoints were the incidence and severity of adverse events. The secondary outcomes included the percentage of excess weight loss and changes in co-morbid status.

Results: The DJBS was endoscopically delivered and retrieved in all patients (mean implant/explant time of 26.6 and 43.3 min, respectively). Of the 12 patients, 10 were able to maintain the device for 12 weeks and 2 underwent explantation after 9 days secondary to poor device placement. Several self-limited adverse events were possibly or definitely related to the device, including 6 episodes of abdominal pain, 18 of nausea, and 16 of vomiting, mainly within 2 weeks of implantation. Two partial pharyngeal tears occurred during explantation. Implant site inflammation was encountered in all patients. No device-related event was considered severe. The average percentage of excess weight loss for the 10 patients with the device in place for 12 weeks was 23.6%, with all patients achieving at least 10% excess weight loss. All 4 diabetic patients had normal fasting plasma glucose levels without hypoglycemic medication for the entire 12 weeks. Of these 4 patients, 3 had decreased hemoglobin A(1c) of > or =.5% by week 12.

Conclusion: The DJBS can be safely delivered and removed endoscopically and left in situ for 12 weeks. The device had a favorable safety and encouraging efficacy profile. Randomized prospective trials are warranted.

PubMed Disclaimer