TagFinder for the quantitative analysis of gas chromatography--mass spectrometry (GC-MS)-based metabolite profiling experiments
- PMID: 18204057
- DOI: 10.1093/bioinformatics/btn023
TagFinder for the quantitative analysis of gas chromatography--mass spectrometry (GC-MS)-based metabolite profiling experiments
Abstract
Motivation: Typical GC-MS-based metabolite profiling experiments may comprise hundreds of chromatogram files, which each contain up to 1000 mass spectral tags (MSTs). MSTs are the characteristic patterns of approximately 25-250 fragment ions and respective isotopomers, which are generated after gas chromatography (GC) by electron impact ionization (EI) of the separated chemical molecules. These fragment ions are subsequently detected by time-of-flight (TOF) mass spectrometry (MS). MSTs of profiling experiments are typically reported as a list of ions, which are characterized by mass, chromatographic retention index (RI) or retention time (RT), and arbitrary abundance. The first two parameters allow the identification, the later the quantification of the represented chemical compounds. Many software tools have been reported for the pre-processing, the so-called curve resolution and deconvolution, of GC-(EI-TOF)-MS files. Pre-processing tools generate numerical data matrices, which contain all aligned MSTs and samples of an experiment. This process, however, is error prone mainly due to (i) the imprecise RI or RT alignment of MSTs and (ii) the high complexity of biological samples. This complexity causes co-elution of compounds and as a consequence non-selective, in other words impure MSTs. The selection and validation of optimal fragment ions for the specific and selective quantification of simultaneously eluting compounds is, therefore, mandatory. Currently validation is performed in most laboratories under human supervision. So far no software tool supports the non-targeted and user-independent quality assessment of the data matrices prior to statistical analysis. TagFinder may fill this gap.
Strategy: TagFinder facilitates the analysis of all fragment ions, which are observed in GC-(EI-TOF)-MS profiling experiments. The non-targeted approach allows the discovery of novel and unexpected compounds. In addition, mass isotopomer resolution is maintained by TagFinder processing. This feature is essential for metabolic flux analyses and highly useful, but not required for metabolite profiling. Whenever possible, TagFinder gives precedence to chemical means of standardization, for example, the use of internal reference compounds for retention time calibration or quantitative standardization. In addition, external standardization is supported for both compound identification and calibration. The workflow of TagFinder comprises, (i) the import of fragment ion data, namely mass, time and arbitrary abundance (intensity), from a chromatography file interchange format or from peak lists provided by other chromatogram pre-processing software, (ii) the annotation of sample information and grouping of samples into classes, (iii) the RI calculation, (iv) the binning of observed fragment ions of equal mass from different chromatograms into RI windows, (v) the combination of these bins, so-called mass tags, into time groups of co-eluting fragment ions, (vi) the test of time groups for intensity correlated mass tags, (vii) the data matrix generation and (viii) the extraction of selective mass tags supported by compound identification. Thus, TagFinder supports both non-targeted fingerprinting analyses and metabolite targeted profiling.
Availability: Exemplary TagFinder workspaces and test data sets are made available upon request to the contact authors. TagFinder is made freely available for academic use from http://www-en.mpimp-golm.mpg.de/03-research/researchGroups/01-dept1/Root_Metabolism/smp/TagFinder/index.html.
Similar articles
-
TagFinder: preprocessing software for the fingerprinting and the profiling of gas chromatography-mass spectrometry based metabolome analyses.Methods Mol Biol. 2012;860:255-86. doi: 10.1007/978-1-61779-594-7_16. Methods Mol Biol. 2012. PMID: 22351182
-
Current challenges and developments in GC-MS based metabolite profiling technology.J Biotechnol. 2006 Jun 25;124(1):312-22. doi: 10.1016/j.jbiotec.2005.12.012. Epub 2006 Jan 24. J Biotechnol. 2006. PMID: 16434119
-
Nonsupervised construction and application of mass spectral and retention time index libraries from time-of-flight gas chromatography-mass spectrometry metabolite profiles.Methods Mol Biol. 2007;358:19-38. doi: 10.1007/978-1-59745-244-1_2. Methods Mol Biol. 2007. PMID: 17035678
-
Role of liquid chromatography-high-resolution mass spectrometry (LC-HR/MS) in clinical toxicology.Clin Toxicol (Phila). 2012 Sep;50(8):733-42. doi: 10.3109/15563650.2012.713108. Epub 2012 Aug 13. Clin Toxicol (Phila). 2012. PMID: 22888997 Review.
-
Gas chromatography/mass spectrometry in metabolic profiling of biological fluids.J Chromatogr B Analyt Technol Biomed Life Sci. 2008 Aug 15;871(2):202-11. doi: 10.1016/j.jchromb.2008.04.033. Epub 2008 Apr 29. J Chromatogr B Analyt Technol Biomed Life Sci. 2008. PMID: 18479983 Review.
Cited by
-
Comprehensive analysis of the GALACTINOL SYNTHASE (GolS) gene family in citrus and the function of CsGolS6 in stress tolerance.PLoS One. 2022 Sep 16;17(9):e0274791. doi: 10.1371/journal.pone.0274791. eCollection 2022. PLoS One. 2022. PMID: 36112700 Free PMC article.
-
Menthol, a unique urinary volatile compound, is associated with chronic inflammation in interstitial cystitis.Sci Rep. 2018 Jul 18;8(1):10859. doi: 10.1038/s41598-018-29085-3. Sci Rep. 2018. PMID: 30022124 Free PMC article.
-
Electron Ionization-Induced Release of Coded Isotopic Reporter Ions in an m/z Zone of Minimal Interference for Quantifiable, Multiplexed GC-MS Analyses.Anal Methods. 2013 Sep 21;5(18):10.1039/C3AY41124A. doi: 10.1039/C3AY41124A. Anal Methods. 2013. PMID: 24235976 Free PMC article.
-
Metabonomics reveals peripheral and central short-chain fatty acid and amino acid dysfunction in a naturally occurring depressive model of macaques.Neuropsychiatr Dis Treat. 2019 May 1;15:1077-1088. doi: 10.2147/NDT.S186071. eCollection 2019. Neuropsychiatr Dis Treat. 2019. PMID: 31118641 Free PMC article.
-
Coupling virus-induced gene silencing to exogenous green fluorescence protein expression provides a highly efficient system for functional genomics in Arabidopsis and across all stages of tomato fruit development.Plant Physiol. 2011 Jul;156(3):1278-91. doi: 10.1104/pp.111.177345. Epub 2011 Apr 29. Plant Physiol. 2011. PMID: 21531899 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous