Functional hemodynamic monitoring and dynamic indices of fluid responsiveness
- PMID: 18212731
Functional hemodynamic monitoring and dynamic indices of fluid responsiveness
Abstract
Knowing whether or not a fluid infusion can improve cardiac output (fluid responsiveness) is crucial when treating hemodynamically unstable patients. Generally, cardiac filling pressures (central venous pressure, pulmonary artery occlusion [''wedge''] pressure) and volumes (end-diastolic left and right ventricular volume) are used, although they are not reliable predictors of fluid responsiveness. For this reason, new indices, the so-called dynamic indices of fluid responsiveness, have been recently introduced in clinical use. If stroke volume, or stroke volume-derived parameters (pulse pressure and aortic flow) show wide variation during mechanical ventilation, a good response to fluid therapy can be predicted. As these indices are based upon the effects of controlled mechanical ventilation on stroke volume, they can be used in deeply sedated or apneic patients whose cardiac rhythm is regular. To overcome these limitations, new dynamic indices have been introduced. Among them, variation of cardiac output induced by passive leg raising (PLR) has raised particular interest since it can identify fluid responders even among spontaneously breathing and non-sinus rhythm patients. Although promising, the dynamic indices of fluid responsiveness have been studied only retrospectively in a relatively small number of patients and evidence that clinical use of these indices can improve outcome is still limited. Further investigations are needed to confirm their clinical validity.
Similar articles
-
Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis.Crit Care Med. 2010 Mar;38(3):819-25. doi: 10.1097/CCM.0b013e3181c8fe7a. Crit Care Med. 2010. PMID: 20016380
-
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.Crit Care Med. 2008 Oct;36(10):2810-6. doi: 10.1097/CCM.0b013e318186b74e. Crit Care Med. 2008. PMID: 18766099
-
Emerging trends in minimally invasive haemodynamic monitoring and optimization of fluid therapy.Eur J Anaesthesiol. 2009 Nov;26(11):893-905. doi: 10.1097/EJA.0b013e3283308e50. Eur J Anaesthesiol. 2009. PMID: 19667998 Review.
-
Invasive measures of left ventricular preload.Curr Opin Crit Care. 2006 Jun;12(3):235-40. doi: 10.1097/01.ccx.0000224868.86205.53. Curr Opin Crit Care. 2006. PMID: 16672783 Review.
-
Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients.Crit Care Med. 2009 Mar;37(3):951-6. doi: 10.1097/CCM.0b013e3181968fe1. Crit Care Med. 2009. PMID: 19237902
Cited by
-
Efficacy of Goal-Directed Fluid Therapy via Pleth Variability Index During Laparoscopic Roux-en-Y Gastric Bypass Surgery in Morbidly Obese Patients.Obes Surg. 2018 Feb;28(2):358-363. doi: 10.1007/s11695-017-2840-1. Obes Surg. 2018. PMID: 28762023 Clinical Trial.
-
Evaluation of the caudal vena cava diameter to abdominal aortic diameter ratio and the caudal vena cava respiratory collapsibility for predicting fluid responsiveness in a heterogeneous population of hospitalized conscious dogs.J Vet Med Sci. 2020 Mar 24;82(3):337-344. doi: 10.1292/jvms.19-0028. Epub 2020 Jan 13. J Vet Med Sci. 2020. PMID: 31932519 Free PMC article.
-
A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness.Crit Care. 2014 May 27;18(3):R108. doi: 10.1186/cc13891. Crit Care. 2014. PMID: 24886990 Free PMC article.
-
Pulse and systolic pressure variation assessment in partially assisted ventilatory support.J Clin Monit Comput. 2008 Oct;22(5):355-9. doi: 10.1007/s10877-008-9142-z. Epub 2008 Oct 9. J Clin Monit Comput. 2008. PMID: 18841485
-
Evaluation of external reference levels for central venous pressure measurements of severely obese patients in the supine position.J Anesth. 2018 Aug;32(4):558-564. doi: 10.1007/s00540-018-2513-9. Epub 2018 May 28. J Anesth. 2018. PMID: 29808259
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials