Analysis of nonstandard noise dosimeter microphone positions
- PMID: 18213533
- DOI: 10.1080/15459620701879438
Analysis of nonstandard noise dosimeter microphone positions
Abstract
This study was conducted as part of a project involving the evaluation of a new type of noise exposure monitoring paradigm. Laboratory tests were conducted to assess how "nonstandard" dosimeter microphones and microphone positions measured noise levels under different acoustical conditions (i.e., diffuse field and direct field). The data presented in this article reflect measurement differences due to microphone position and mounting/supporting structure only and are not an evaluation of any particular complete dosimeter system. To varying degrees, the results obtained with the dosimeter microphones used in this study differed from the reference results obtained in the unperturbed (subject absent) sound field with a precision (suitable for use in an ANSI Type 1 sound level meter) (1)/(2)-inch (12.7 mm) measurement microphone. Effects of dosimeter microphone placement in a diffuse field were found to be minor for most of the test microphones/locations, while direct field microphone placement effects were found to be quite large depending on the microphone position and supporting structure, sound source location, and noise spectrum.
Similar articles
-
A field evaluation of noise measuring instruments.Am Ind Hyg Assoc J. 1983 Sep;44(9):665-70. doi: 10.1080/15298668391405535. Am Ind Hyg Assoc J. 1983. PMID: 6637813
-
Improving the accuracy of smart devices to measure noise exposure.J Occup Environ Hyg. 2016 Nov;13(11):840-6. doi: 10.1080/15459624.2016.1183014. J Occup Environ Hyg. 2016. PMID: 27163833 Free PMC article.
-
A note on determination of the diffuse-field sensitivity of microphones using the reciprocity technique.J Acoust Soc Am. 2008 Sep;124(3):1505-12. doi: 10.1121/1.2950089. J Acoust Soc Am. 2008. PMID: 19045642
-
Measuring sound in hospital nurseries.J Perinatol. 2000 Dec;20(8 Pt 2):S100-4. doi: 10.1038/sj.jp.7200440. J Perinatol. 2000. PMID: 11190688 Review.
-
Micro-Electro-Mechanical Systems Microphones: A Brief Review Emphasizing Recent Advances in Audible Spectrum Applications.Micromachines (Basel). 2024 Feb 29;15(3):352. doi: 10.3390/mi15030352. Micromachines (Basel). 2024. PMID: 38542599 Free PMC article. Review.
Cited by
-
Characteristics of Real-World Signal to Noise Ratios and Speech Listening Situations of Older Adults With Mild to Moderate Hearing Loss.Ear Hear. 2018 Mar/Apr;39(2):293-304. doi: 10.1097/AUD.0000000000000486. Ear Hear. 2018. PMID: 29466265 Free PMC article.
-
Construction Site Noise Exposure Assessment Using Binaural Measurements and Analysis.Safety (Basel). 2024 Dec;10(4):92. doi: 10.3390/safety10040092. Epub 2024 Oct 30. Safety (Basel). 2024. PMID: 40026880 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical