Conformational and quantitative characterization of lysozyme extracted from galyfilcon and senofilcon silicone hydrogel contact lenses
- PMID: 18214737
- DOI: 10.1080/02713680701830278
Conformational and quantitative characterization of lysozyme extracted from galyfilcon and senofilcon silicone hydrogel contact lenses
Abstract
Purpose: To compare two solvents for retrieval of lysozyme deposited on a silicone hydrogel (SH) contact lens material galyfilcon A (GA; Acuvue Advance).
Methods: Two buffers used were 50:50 acetonitrile/0.02% trifluoroacetic acid (buffer 1) and 50:50 acetonitrile/50 mM NaOH (buffer 2).
Results: Extraction efficiency from GA lenses was 74% (buffer 1) and 83% (buffer 2). Buffer 2 decreased lysozyme activity > buffer 1. Ex vivo GA lenses showed total protein deposition of 2-16 microg/lens with total lysozyme deposition of 0.3-3.9 microg/lens.
Conclusions: We have developed a low acid strength extraction buffer that can be used to efficiently extract active lysozyme protein from novel siloxane-based contact lens materials.
Similar articles
-
Quantity and conformation of lysozyme deposited on conventional and silicone hydrogel contact lens materials using an in vitro model.Eye Contact Lens. 2007 May;33(3):138-43. doi: 10.1097/01.icl.0000244155.87409.f6. Eye Contact Lens. 2007. PMID: 17502748
-
Ex vivo protein deposition on bi-weekly silicone hydrogel contact lenses.Optom Vis Sci. 2009 Nov;86(11):1241-9. doi: 10.1097/OPX.0b013e3181bbc1b3. Optom Vis Sci. 2009. PMID: 19770811 Clinical Trial.
-
Extraction efficiency of an extraction buffer used to quantify lysozyme deposition on conventional and silicone hydrogel contact lens materials.Eye Contact Lens. 2007 Jul;33(4):169-73. doi: 10.1097/01.icl.0000248155.23800.20. Eye Contact Lens. 2007. PMID: 17630622
-
Deposition on silicone hydrogel lenses.Eye Contact Lens. 2013 Jan;39(1):20-23. doi: 10.1097/ICL.0b013e318275305b. Eye Contact Lens. 2013. PMID: 23266585 Review.
-
Biocompatibility in the development of silicone-hydrogel lenses.Eye Contact Lens. 2013 Jan;39(1):13-9. doi: 10.1097/ICL.0b013e31827dbb00. Eye Contact Lens. 2013. PMID: 23271477 Review.
Cited by
-
Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems.Clin Ophthalmol. 2021 Apr 23;15:1727-1733. doi: 10.2147/OPTH.S296116. eCollection 2021. Clin Ophthalmol. 2021. PMID: 33935489 Free PMC article.
-
Proteomic analysis of protein deposits on worn daily wear silicone hydrogel contact lenses.Mol Vis. 2008;14:2016-24. Epub 2008 Nov 7. Mol Vis. 2008. PMID: 18989384 Free PMC article.
-
Evaluation of extractants and precipitants in tear film proteomic analyses.Optom Vis Sci. 2010 Nov;87(11):854-60. doi: 10.1097/OPX.0b013e3181f6fb71. Optom Vis Sci. 2010. PMID: 20852451 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources