Abstract
A post-processing technique has been developed to suppress the magnetic resonance imaging (MRI) artifact arising from object planar rigid motion. In two-dimensional Fourier transform (2-DFT) MRI, rotational and translational motions of the target during magnetic resonance magnetic resonance (MR) scan respectively impose nonuniform sampling and a phase error an the collected MRI signal. The artifact correction method introduced considers the following three conditions: (1) for planar rigid motion with known parameters, a reconstruction algorithm based on bilinear interpolation and the super-position method is employed to remove the MRI artifact, (2) for planar rigid motion with known rotation angle and unknown translational motion (including an unknown rotation center), first, a super-position bilinear interpolation algorithm is used to eliminate artifact due to rotation about the center of the imaging plane, following which a phase correction algorithm is applied to reduce the remaining phase error of the MRI signal, and (3) to estimate unknown parameters of a rigid motion, a minimum energy method is proposed which utilizes the fact that planar rigid motion increases the measured energy of an ideal MR image outside the boundary of the imaging object; by using this property all unknown parameters of a typical rigid motion are accurately estimated in the presence of noise. To confirm the feasibility of employing the proposed method in a clinical setting, the technique was used to reduce unknown rigid motion artifact arising from the head movements of two volunteers.
Similar articles
-
An improved method for MRI artifact correction due to translational motion in the imaging plane.IEEE Trans Med Imaging. 1995;14(3):471-9. doi: 10.1109/42.414612. IEEE Trans Med Imaging. 1995. PMID: 18215851
-
[Inverse iterative correction for translational motion artifact of magnetic resonance imaging based on histogram entropy minimization].Di Yi Jun Yi Da Xue Xue Bao. 2005 Jun;25(6):655-9. Di Yi Jun Yi Da Xue Xue Bao. 2005. PMID: 15958301 Chinese.
-
Automatic correction of in-plane bulk motion artifacts in self-navigated radial MRI.Magn Reson Imaging. 2008 Apr;26(3):367-78. doi: 10.1016/j.mri.2007.08.001. Epub 2008 Feb 20. Magn Reson Imaging. 2008. PMID: 18068927
-
An improved algorithm for rotational motion artifact suppression in MRI.IEEE Trans Med Imaging. 1998 Apr;17(2):310-7. doi: 10.1109/42.700744. IEEE Trans Med Imaging. 1998. PMID: 9688164
-
[The clinical application of diffusion weighted magnetic resonance imaging to acute cerebrovascular disorders].No To Shinkei. 1998 Sep;50(9):787-95. No To Shinkei. 1998. PMID: 9789301 Review. Japanese.
Cited by
-
Intrinsic detection of motion in segmented sequences.Magn Reson Med. 2011 Apr;65(4):1084-9. doi: 10.1002/mrm.22681. Epub 2010 Nov 3. Magn Reson Med. 2011. PMID: 21413072 Free PMC article.
-
CINE turbo spin echo imaging.Magn Reson Med. 2011 Nov;66(5):1286-92. doi: 10.1002/mrm.22909. Epub 2011 Jun 23. Magn Reson Med. 2011. PMID: 21702060 Free PMC article.
LinkOut - more resources
Full Text Sources
Other Literature Sources