. 1996;15(6):768-84.
doi: 10.1109/42.544495.

MRI artifact cancellation due to rigid motion in the imaging plane

Affiliations

MRI artifact cancellation due to rigid motion in the imaging plane

R A Zoroofi et al. IEEE Trans Med Imaging. 1996.

Abstract

A post-processing technique has been developed to suppress the magnetic resonance imaging (MRI) artifact arising from object planar rigid motion. In two-dimensional Fourier transform (2-DFT) MRI, rotational and translational motions of the target during magnetic resonance magnetic resonance (MR) scan respectively impose nonuniform sampling and a phase error an the collected MRI signal. The artifact correction method introduced considers the following three conditions: (1) for planar rigid motion with known parameters, a reconstruction algorithm based on bilinear interpolation and the super-position method is employed to remove the MRI artifact, (2) for planar rigid motion with known rotation angle and unknown translational motion (including an unknown rotation center), first, a super-position bilinear interpolation algorithm is used to eliminate artifact due to rotation about the center of the imaging plane, following which a phase correction algorithm is applied to reduce the remaining phase error of the MRI signal, and (3) to estimate unknown parameters of a rigid motion, a minimum energy method is proposed which utilizes the fact that planar rigid motion increases the measured energy of an ideal MR image outside the boundary of the imaging object; by using this property all unknown parameters of a typical rigid motion are accurately estimated in the presence of noise. To confirm the feasibility of employing the proposed method in a clinical setting, the technique was used to reduce unknown rigid motion artifact arising from the head movements of two volunteers.

PubMed Disclaimer

Similar articles

Cited by

  • Intrinsic detection of motion in segmented sequences.
    Mendes J, Parker DL. Mendes J, et al. Magn Reson Med. 2011 Apr;65(4):1084-9. doi: 10.1002/mrm.22681. Epub 2010 Nov 3. Magn Reson Med. 2011. PMID: 21413072 Free PMC article.
  • CINE turbo spin echo imaging.
    Mendes J, Parker DL, Hulet J, Treiman GS, Kim SE. Mendes J, et al. Magn Reson Med. 2011 Nov;66(5):1286-92. doi: 10.1002/mrm.22909. Epub 2011 Jun 23. Magn Reson Med. 2011. PMID: 21702060 Free PMC article.

LinkOut - more resources