Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Apr;19(4):1839-50.
doi: 10.1007/s10856-008-3384-7. Epub 2008 Jan 25.

Surface modifications of silicon nitride for cellular biosensor applications

Affiliations

Surface modifications of silicon nitride for cellular biosensor applications

Johan Gustavsson et al. J Mater Sci Mater Med. 2008 Apr.

Abstract

Thin films of silicon nitride (Si3N4) can be used in several kinds of micro-sized biosensors as a material to monitor fine environmental changes related to the process of bone formation in vitro. We found however that Si3N4 does not provide optimal conditions for osseointegration as osteoblast-like MG-63 cells tend to detach from the surface when cultured over confluence. Therefore Si3N4 was modified with self-assembled monolayers bearing functional end groups of primary amine (NH2) and carboxyl (COOH) respectively. Both these modifications enhanced the interaction with confluent cell layers and thus improve osseointegration over Si3N4. Furthermore it was observed that the NH2 functionality increased the adsorption of fibronectin (FN), promoted cell proliferation, but delayed the differentiation. We also studied the fate of pre-adsorbed and secreted FN from cells to learn more about the impact of above functionalities for the development of provisional extracellular matrix on materials interface. Taken together our data supports that Si3N4 has low tissue integration but good cellular biocompatibility and thus is appropriate in cellular biosensor applications such as the ion-sensitive field effect transistor (ISFET). COOH and NH2 chemistries generally improve the interfacial tissue interaction with the sensor and they are therefore suitable substrates for monitoring cellular growth or matrix deposition using electrical impedance spectroscopy.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Proc Natl Acad Sci U S A. 2005 Apr 26;102(17):5953-7 - PubMed
    1. J Biomed Mater Res. 2000 Apr;50(1):43-9 - PubMed
    1. J Biomed Mater Res A. 2003 Aug 1;66(2):247-59 - PubMed
    1. Biomaterials. 2004 Jun;25(14):2721-30 - PubMed
    1. Biomaterials. 2006 Jan;27(2):234-45 - PubMed

Publication types

LinkOut - more resources