MR systems for MRI-guided interventions
- PMID: 18219680
- DOI: 10.1002/jmri.21269
MR systems for MRI-guided interventions
Abstract
The field of MR imaging has grown from diagnosis via morphologic imaging to more sophisticated diagnosis via both physiologic and morphologic imaging and finally to the guidance and control of interventions. A wide variety of interventional procedures from open brain surgeries to noninvasive focused ultrasound ablations have been guided with MR and the differences between diagnostic and interventional MR imaging systems have motivated the creation of a new field within MR. This review discusses the various systems that research groups and vendors have designed to meet the requirements of interventional MR and suggest possible solutions to those requirements that have not yet been met. The common requirements created by MR imaging guidance of interventional procedures are reviewed and different imaging system designs will be independently considered. The motivation and history of the different designs are discussed and the ability of the designs to satisfy the requirements is analyzed.
(Copyright) 2008 Wiley-Liss, Inc.
Similar articles
-
Navigation concepts for MR image-guided interventions.J Magn Reson Imaging. 2008 Feb;27(2):276-91. doi: 10.1002/jmri.21262. J Magn Reson Imaging. 2008. PMID: 18219682 Review.
-
The interventional MR imaging suite: magnet designs and equipment requirements.Magn Reson Imaging Clin N Am. 2005 Aug;13(3):401-13. doi: 10.1016/j.mric.2005.04.014. Magn Reson Imaging Clin N Am. 2005. PMID: 16084409
-
MR-guided intravascular interventions: techniques and applications.J Magn Reson Imaging. 2008 Feb;27(2):326-38. doi: 10.1002/jmri.21271. J Magn Reson Imaging. 2008. PMID: 18219686 Review.
-
Intraoperative MRI: technology, systems, and application to pediatric brain tumors.Surg Technol Int. 2007;16:236-43. Surg Technol Int. 2007. PMID: 17429795 Review.
-
MRI-Guided percutaneous biopsy of breast lesions: materials, techniques, success rates, and management in patients with suspected radiologic-pathologic mismatch.Magn Reson Imaging Clin N Am. 2006 Aug;14(3):411-25, viii. doi: 10.1016/j.mric.2006.10.002. Magn Reson Imaging Clin N Am. 2006. PMID: 17098182 Review.
Cited by
-
Origins of intraoperative MRI.Magn Reson Imaging Clin N Am. 2010 Feb;18(1):1-10. doi: 10.1016/j.mric.2009.09.001. Magn Reson Imaging Clin N Am. 2010. PMID: 19962089 Free PMC article.
-
Occupational exposure in MRI.Br J Radiol. 2012 Apr;85(1012):293-312. doi: 10.1259/bjr/30146162. Br J Radiol. 2012. PMID: 22457400 Free PMC article. Review.
-
MR fluoroscopy in vascular and cardiac interventions (review).Int J Cardiovasc Imaging. 2012 Jan;28(1):117-37. doi: 10.1007/s10554-010-9774-1. Epub 2011 Feb 26. Int J Cardiovasc Imaging. 2012. PMID: 21359519 Free PMC article. Review.
-
Origins of intraoperative MRI.Neurosurg Clin N Am. 2009 Apr;20(2):137-46. doi: 10.1016/j.nec.2009.04.002. Neurosurg Clin N Am. 2009. PMID: 19555875 Free PMC article.
-
Augmented reality visualisation using an image overlay system for MR-guided interventions: technical performance of spine injection procedures in human cadavers at 1.5 Tesla.Eur Radiol. 2013 Jan;23(1):235-45. doi: 10.1007/s00330-012-2569-0. Epub 2012 Jul 15. Eur Radiol. 2013. PMID: 22797956
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous