Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator)
- PMID: 18221427
- PMCID: PMC2390770
- DOI: 10.1111/j.1399-5448.2007.00301.x
Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator)
Abstract
Background: There are no published guidelines for use of real-time continuous glucose monitoring data by a patient; we therefore developed the DirecNet Applied Treatment Algorithm (DATA). The DATA provides algorithms for making diabetes management decisions using glucose values: (i) in real time which include the direction and rate of change of glucose levels, and (ii) retrospectively based on downloaded sensor data.
Objective: To evaluate the use and effectiveness of the DATA in children with diabetes using a real-time continuous glucose sensor (the FreeStyle Navigator).
Subjects: Thirty children and adolescents (mean +/- standard deviation age = 11.2 +/- 4.1 yr) receiving insulin pump therapy.
Methods: Subjects were instructed on use of the DATA and were asked to download their Navigator weekly to review glucose patterns. An Algorithm Satisfaction Questionnaire was completed at 3, 7, and 13 wk.
Results: At 13 wk, all of the subjects and all but one parent thought that the DATA gave good, clear directions for insulin dosing, and thought the guidelines improved their postprandial glucose levels. In responding to alarms, 86% of patients used the DATA at least 50% of the time at 3 wk, and 59% reported doing so at 13 wk. Similar results were seen in using the DATA to adjust premeal bolus doses of insulin.
Conclusions: These results show the feasibility of implementing the DATA when real-time continuous glucose monitoring is initiated and support its use in future clinical trials of real-time continuous glucose monitoring.
Similar articles
-
Continuous glucose monitoring in children with type 1 diabetes.J Pediatr. 2007 Oct;151(4):388-93, 393.e1-2. doi: 10.1016/j.jpeds.2007.03.047. Epub 2007 Aug 24. J Pediatr. 2007. PMID: 17889075 Free PMC article. Clinical Trial.
-
Prolonged use of continuous glucose monitors in children with type 1 diabetes on continuous subcutaneous insulin infusion or intensive multiple-daily injection therapy.Pediatr Diabetes. 2009 Apr;10(2):91-6. doi: 10.1111/j.1399-5448.2008.00476.x. Epub 2008 Oct 20. Pediatr Diabetes. 2009. PMID: 19175899
-
FreeStyle Navigator Continuous Glucose Monitoring System with TRUstart algorithm, a 1-hour warm-up time.J Diabetes Sci Technol. 2011 Jan 1;5(1):99-106. doi: 10.1177/193229681100500114. J Diabetes Sci Technol. 2011. PMID: 21303631 Free PMC article. Clinical Trial.
-
Diabetes technology and treatments in the paediatric age group.Int J Clin Pract Suppl. 2011 Feb;(170):76-82. doi: 10.1111/j.1742-1241.2010.02582.x. Int J Clin Pract Suppl. 2011. PMID: 21323816 Review.
-
Optimising use of rate-of-change trend arrows for insulin dosing decisions using the FreeStyle Libre flash glucose monitoring system.Diab Vasc Dis Res. 2019 Jan;16(1):3-12. doi: 10.1177/1479164118795252. Epub 2018 Sep 3. Diab Vasc Dis Res. 2019. PMID: 30175925 Review.
Cited by
-
Practical Approach to Using Trend Arrows on Real-Time Continuous Glucose Monitoring System in Type 1 Diabetes Adolescents Living Camp Setting Treated With Multiple Daily Injection or Continuous Subcutaneous Insulin Infusion Insulin Therapy.J Diabetes Sci Technol. 2021 Sep;15(5):1098-1103. doi: 10.1177/1932296820934803. Epub 2020 Jun 19. J Diabetes Sci Technol. 2021. PMID: 32552001 Free PMC article.
-
Educating families on real time continuous glucose monitoring: the DirecNet navigator pilot study experience.Diabetes Educ. 2009 Jan-Feb;35(1):124-35. doi: 10.1177/0145721708325157. Diabetes Educ. 2009. PMID: 19244568 Free PMC article.
-
Retrospective Analysis of Continuous Glucose Monitoring Data With the Surveillance Error Grid Supports Nonadjunctive Dosing Decisions.J Diabetes Sci Technol. 2017 Sep;11(5):942-946. doi: 10.1177/1932296817694180. Epub 2017 Feb 15. J Diabetes Sci Technol. 2017. PMID: 28617187 Free PMC article.
-
A Simplified Approach Using Rate of Change Arrows to Adjust Insulin With Real-Time Continuous Glucose Monitoring.J Diabetes Sci Technol. 2017 Nov;11(6):1063-1069. doi: 10.1177/1932296817723260. Epub 2017 Sep 8. J Diabetes Sci Technol. 2017. PMID: 28884599 Free PMC article. No abstract available.
-
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes-2025.Diabetes Care. 2025 Jan 1;48(1 Suppl 1):S181-S206. doi: 10.2337/dc25-S009. Diabetes Care. 2025. PMID: 39651989 Review.
References
-
- Diabetes Research in Children Network (DirecNet) Study Group. Continuous Glucose Monitoring in Children with Type 1 Diabetes. The Journal of Pediatrics. 2007 In press. - PubMed
-
- Boukhors Y, Rabasa-Lhoret R, Langelier H, Soultan M, Lacroix A, Chiasson J. The use of information technology for the management of intensive insulin therapy in Type 1 Diabetes Mellitus. Diabetes Metab. 2003;29:619–627. - PubMed
-
- Miyako K, Kuromaru R, Kohno H, Hara T. Improved diabetes control by using ‘Close Adjustment Algorithms’. Pediatr Int. 2004;46:678–684. - PubMed
-
- Skyler J, Skyler D, Seigler D, O’Sullivan M. Algorithms for adjustment of insulin dosage by patients who monitor blood glucose. Diabetes Care. 1981;4:311–318. - PubMed
-
- Davidson P, Steed R, Bode B. Glucommander: a computer-directed intravenous insulin system shown to be safe, simple, and effective in 120,618 hours of operation. Diabetes Care. 2005;28:2418–2423. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical