Technical aspects of pacing in adult and pediatric congenital heart disease
- PMID: 18226031
- DOI: 10.1111/j.1540-8159.2008.00951.x
Technical aspects of pacing in adult and pediatric congenital heart disease
Abstract
As intuitive as it might appear, it must be remembered that children are not little adults and congenital heart defects do not equate to normal cardiac anatomy. In addition, repaired congenital heart defects in adults (ACHD) might also not equate to normal anatomy. In each of these clinical situations, pacemaker device therapy may dramatically differ from most of the published information available in the field of internal medicine cardiology. Since there are now more patients with structural congenital heart defects over than under the age of 21 years, all present and future generations of pacemaker implanters need to recognize the plethora of anatomical and structural nuances potentially associated with the implantation of device therapy in this continually expanding patient population. Fortunately, advances in pacemaker and lead technology over the past 20 years, which now permit precise implantation at selective endocardial sites other than the right ventricular apex or atrial appendage and improved epicardial leads, have greatly facilitated optimization of pacing therapy. Whereas past interests have focused on lead performance issues such as dislodgement, fractures, and exit block, improvements in lead design technologies now permit more interest in maintaining or improving paced myocardial function by optimizing lead placement at alternate or more select sites. This article reviews recent applications and future directions of these pacing technologies and emphasizes differences among patients with congenital heart defects.
Similar articles
-
Indications for pacing in patients with congenital heart disease.Pacing Clin Electrophysiol. 2008 Feb;31 Suppl 1:S17-20. doi: 10.1111/j.1540-8159.2008.00948.x. Pacing Clin Electrophysiol. 2008. PMID: 18226027 Review.
-
Pediatric cardiac resynchronization pacing therapy.Curr Opin Cardiol. 2007 Mar;22(2):72-6. doi: 10.1097/HCO.0b013e328014a849. Curr Opin Cardiol. 2007. PMID: 17284983 Review.
-
Cardiac resynchronization therapy in pediatric and congenital heart disease.Pacing Clin Electrophysiol. 2008 Feb;31 Suppl 1:S21-3. doi: 10.1111/j.1540-8159.2008.00949.x. Pacing Clin Electrophysiol. 2008. PMID: 18226029 Review.
-
Implantable cardioverter-defibrillators in children.Pacing Clin Electrophysiol. 2008 Feb;31 Suppl 1:S32-4. doi: 10.1111/j.1540-8159.2008.00952.x. Pacing Clin Electrophysiol. 2008. PMID: 18226032 Review.
-
Efficacy of prophylactic epicardial pacing leads in children and young adults.Ann Thorac Surg. 2004 Jul;78(1):197-202; discussion 202-3. doi: 10.1016/j.athoracsur.2004.02.008. Ann Thorac Surg. 2004. PMID: 15223427 Review.
Cited by
-
Pacing device therapy in infants and children: a review.J Artif Organs. 2013 Mar;16(1):23-33. doi: 10.1007/s10047-012-0668-y. Epub 2012 Oct 27. J Artif Organs. 2013. PMID: 23104398 Review.
-
Old but not forgotten: Creative use of abandoned epicardial leads after more than 2 decades.HeartRhythm Case Rep. 2017 Oct 19;3(12):559-561. doi: 10.1016/j.hrcr.2017.05.006. eCollection 2017 Dec. HeartRhythm Case Rep. 2017. PMID: 29296574 Free PMC article. No abstract available.
-
Angiography-guided mid/high septal implantation of ventricular leads in patients with congenital heart disease.J Arrhythm. 2021 Sep 17;37(6):1512-1521. doi: 10.1002/joa3.12636. eCollection 2021 Dec. J Arrhythm. 2021. PMID: 34887956 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous