Abstract
Purpose: To retrospectively compare the accuracy of digital versus film mammography in population subgroups of the Digital Mammographic Imaging Screening Trial (DMIST) defined by combinations of age, menopausal status, and breast density, by using either biopsy results or follow-up information as the reference standard.
Materials and methods: DMIST included women who underwent both digital and film screening mammography. Institutional review board approval at all participating sites and informed consent from all participating women in compliance with HIPAA was obtained for DMIST and this retrospective analysis. Areas under the receiver operating characteristic curve (AUCs) for each modality were compared within each subgroup evaluated (age < 50 vs 50-64 vs >or= 65 years, dense vs nondense breasts at mammography, and pre- or perimenopausal vs postmenopausal status for the two younger age cohorts [10 new subgroups in toto]) while controlling for multiple comparisons (P < .002 indicated a significant difference). All DMIST cancers were evaluated with respect to mammographic detection method (digital vs film vs both vs neither), mammographic lesion type (mass, calcifications, or other), digital machine type, mammographic and pathologic size and diagnosis, existence of prior mammographic study at time of interpretation, months since prior mammographic study, and compressed breast thickness.
Results: Thirty-three centers enrolled 49 528 women. Breast cancer status was determined for 42,760 women, the group included in this study. Pre- or perimenopausal women younger than 50 years who had dense breasts at film mammography comprised the only subgroup for which digital mammography was significantly better than film (AUCs, 0.79 vs 0.54; P = .0015). Breast Imaging Reporting and Data System-based sensitivity in this subgroup was 0.59 for digital and 0.27 for film mammography. AUCs were not significantly different in any of the other subgroups. For women aged 65 years or older with fatty breasts, the AUC showed a nonsignificant tendency toward film being better than digital mammography (AUCs, 0.88 vs 0.70; P = .0025).
Conclusion: Digital mammography performed significantly better than film for pre- and perimenopausal women younger than 50 years with dense breasts, but film tended nonsignificantly to perform better for women aged 65 years or older with fatty breasts.
(c) RSNA, 2008.
Figures
Comment in
-
A limitation of ACRIN DMIST.Radiology. 2008 Aug;248(2):702; author reply 702-3. doi: 10.1148/radiol.2482080235. Radiology. 2008. PMID: 18641261 No abstract available.
-
DMIST results: technologic or observer variability?Radiology. 2008 Aug;248(2):703; author reply 703. doi: 10.1148/radiol.2482080378. Radiology. 2008. PMID: 18641262 No abstract available.
-
Retrospective analyses of pivotal prospective studies with population segmentation: statistically based inferences and clinical relevance.Acad Radiol. 2008 Nov;15(11):1458-62. doi: 10.1016/j.acra.2008.06.008. Acad Radiol. 2008. PMID: 18995196
References
-
- Pisano ED, Gatsonis C, Yaffe M, et al. American College of Radiology Imaging Network digital mammographic imaging screening trial: objectives and methodology. Radiology 2005;236(2):404–412. - PubMed
-
- Pisano ED, Gatsonis C, Hendrick E, et al. Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 2005;353(17):1773–1783. [Published correction appears in N Engl J Med 2006;355(17):1840.] - PubMed
-
- Keen JD. Digital and film mammography. N Engl J Med 2006;354(7):765–767. - PubMed
-
- Carney PA, Miglioretti DL, Yankaskas BC, et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Intern Med 2003;138(3):168–175. [Published correction appears in Ann Intern Med 2003;138(9):771.] - PubMed
-
- Pisano ED. Digital mammography: what next? J Am Coll Radiol 2006;3(8):583–585. - PubMed