Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents
Abstract
A novel technique for the selective detection of ultrasound contrast agents, called pulse inversion Doppler, has been developed. In this technique, a conventional Doppler or color Doppler pulse sequence is modified by inverting every second transmit pulse. Either conventional or harmonic Doppler processing is then performed on the received echoes. In the resulting Doppler spectra, Doppler shifts from linear and nonlinear scattering are separated into two distinct regions that can be analyzed separately or combined to estimate the ratio of nonlinear to linear scattering from a region of tissue. The maximum Doppler shift that can be detected is 1/2 the normal Nyquist limit. This has the advantage over conventional harmonic Doppler that it can function over the entire bandwidth of the echo signal, thus achieving superior spatial resolution in the Doppler image. In vitro measurements comparing flowing agent and cellulose particles suggest that pulse inversion Doppler can provide 3 to 10 dB more agent to tissue contrast than harmonic imaging with similar pulses. Similar measurements suggest that broadband pulse inversion Doppler can provide up to 16 dB more contrast than broadband conventional Doppler. Nonlinear propagation effects limit the maximum contrast obtainable with both harmonic and pulse inversion Doppler techniques.
Similar articles
-
Suppression of tissue harmonics for pulse-inversion contrast imaging using time reversal.Phys Med Biol. 2008 Oct 7;53(19):5469-80. doi: 10.1088/0031-9155/53/19/013. Epub 2008 Sep 2. Phys Med Biol. 2008. PMID: 18765888
-
Numerical modeling of microbubble backscatter to optimize ultrasound particle image velocimetry imaging: initial studies.Ultrasonics. 2004 Aug;42(10):1111-21. doi: 10.1016/j.ultras.2004.02.021. Ultrasonics. 2004. PMID: 15234173
-
Comparison of pulse subtraction Doppler and pulse inversion Doppler.IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Jan;58(1):73-81. doi: 10.1109/TUFFC.2011.1775. IEEE Trans Ultrason Ferroelectr Freq Control. 2011. PMID: 21244976
-
Instrumentation for contrast echocardiography.Echocardiography. 2002 Apr;19(3):241-58. doi: 10.1046/j.1540-8175.2002.00241.x. Echocardiography. 2002. PMID: 12022934 Review.
-
Ultrasound contrast imaging: current and new potential methods.Ultrasound Med Biol. 2000 Jul;26(6):965-75. doi: 10.1016/s0301-5629(00)00229-5. Ultrasound Med Biol. 2000. PMID: 10996696 Review.
Cited by
-
Real-time targeted molecular imaging using singular value spectra properties to isolate the adherent microbubble signal.Phys Med Biol. 2012 Aug 21;57(16):5275-93. doi: 10.1088/0031-9155/57/16/5275. Epub 2012 Aug 1. Phys Med Biol. 2012. PMID: 22853933 Free PMC article.
-
The AFSUMB Consensus Statements and Recommendations for the Clinical Practice of Contrast-Enhanced Ultrasound using Sonazoid.J Med Ultrasound. 2020 May 25;28(2):59-82. doi: 10.4103/JMU.JMU_124_19. eCollection 2020 Apr-Jun. J Med Ultrasound. 2020. PMID: 32874864 Free PMC article.
-
Ultrasound modulated optical tomography contrast enhancement with non-linear oscillation of microbubbles.Quant Imaging Med Surg. 2015 Feb;5(1):9-16. doi: 10.3978/j.issn.2223-4292.2014.11.30. Quant Imaging Med Surg. 2015. PMID: 25694948 Free PMC article.
-
Targeting of microbubbles: contrast agents for ultrasound molecular imaging.J Drug Target. 2018 Jun-Jul;26(5-6):420-434. doi: 10.1080/1061186X.2017.1419362. Epub 2018 Jan 9. J Drug Target. 2018. PMID: 29258335 Free PMC article. Review.
-
Contrast enhanced maximum intensity projection ultrasound imaging for assessing angiogenesis in murine glioma and breast tumor models: A comparative study.Ultrasonics. 2011 Apr;51(3):382-9. doi: 10.1016/j.ultras.2010.11.004. Epub 2010 Nov 18. Ultrasonics. 2011. PMID: 21144542 Free PMC article.
LinkOut - more resources
Other Literature Sources
Miscellaneous