Does carotid stent cell design matter?
- PMID: 18239162
- DOI: 10.1161/STROKEAHA.107.499145
Does carotid stent cell design matter?
Abstract
Background and purpose: Carotid stent cell design has recently been suggested to be a determinant of periprocedural and early postprocedural neurologic complications. We investigated the impact of closed- versus open-cell stent design on neurologic adverse events and mortality after carotid artery stenting.
Methods: We studied 1684 consecutive patients (1010 asymptomatic, 674 symptomatic) from 10 European centers who underwent carotid artery stenting with either closed-cell (n=859, 51%) or open-cell (n=825, 49%) design stents. Rates of transient ischemic attack, stroke, and death on the day of the procedure (acute events) and from day 1 to day 30 after the procedure (subacute events) were analyzed (95% CIs).
Results: Combined transient ischemic attack, stroke, or death rates, and stroke or death rates within 30 days of treatment were 6.1% (95% CI, 5.0 to 7.2) and 3.1% (95% CI, 2.3 to 3.9) for the closed-cell design versus 4.1% (95% CI, 3.2 to 5.0) and 2.4% (95% CI, 1.7 to 3.1) for the open-cell design stents (P=0.077, P=0.38), respectively, without significant differences in asymptomatic and symptomatic patients. By propensity-score-adjusted multivariable analysis, the open-cell carotid stent design was not associated with a differential risk for combined acute and subacute neurologic complications compared with closed-cell stents (adjusted odds ratio=0.84, P=0.53). When analyzed separately, the risk for acute events on the day of the procedure (adjusted odds ratio=0.83, P=0.57) and the risk for subacute events at days 1 to 30 (adjusted odds ratio=1.61, P=0.51) also were not significantly different between the groups.
Conclusions: Current data do not support the superiority of a specific carotid stent cell design with respect to neurologic complications, stroke, and mortality risk.
Comment in
-
Size matters! Stent-length is associated with thrombembolic complications after carotid artery stenting.Stroke. 2008 Aug;39(8):e131-2; author reply e133. doi: 10.1161/STROKEAHA.108.522219. Epub 2008 Jun 26. Stroke. 2008. PMID: 18583551 No abstract available.
-
Carotid stent cell design: lack of benefit or lack of evidence?Stroke. 2008 Aug;39(8):e130; author reply e133. doi: 10.1161/STROKEAHA.108.521534. Epub 2008 Jun 26. Stroke. 2008. PMID: 18583552 No abstract available.
-
Two different studies on carotid stent cell design importance, or are we just saying the same thing?Stroke. 2008 Aug;39(8):e129; author reply e133. doi: 10.1161/STROKEAHA.108.519389. Epub 2008 Jun 26. Stroke. 2008. PMID: 18583553 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical