Dental bioaerosol as an occupational hazard in a dentist's workplace
- PMID: 18247451
Dental bioaerosol as an occupational hazard in a dentist's workplace
Abstract
Many-year studies on aerosols as an infection vector, despite their wide range, ignored dental aerosol. All procedures performed with the use of dental unit handpieces cause the formation of aerosol and splatter which are commonly contaminated with bacteria, viruses, fungi, often also with blood. Aerosols are liquid and solid particles, 50 microm or less in diameter, suspended in air. Splatter is usually described as a mixture of air, water and/or solid substances; water droplets in splatter are from 50 microm to several millimetres in diameter and are visible to the naked eye. The most intensive aerosol and splatter emission occurs during the work of an ultrasonic scaler tip and a bur on a high-speed handpiece. Air-water aerosol produced during dental treatment procedures emerges from a patient's mouth and mixes with the surrounding air, thus influencing its composition. Because air contained in this space is the air breathed by both dentist and patient, its composition is extremely important as a potential threat to the dentist's health. According to the author, insufficient awareness of health risk, working habits, and economic factors are the reasons why dentists do not apply the available and recommended methods of protection against the influence of bioaerosol and splatter. Behaviour protecting a dentist and an assistant from the threat resulting from the influence of dental aerosol cannot be limited to isolated actions. The author, on the basis of the literature and own research, characterizes bioaerosol and splatter in a dental surgery and reviews a full range of protective measures against these risk factors.
Similar articles
-
Aerosol and splatter contamination from the operative site during ultrasonic scaling.J Am Dent Assoc. 1998 Sep;129(9):1241-9. doi: 10.14219/jada.archive.1998.0421. J Am Dent Assoc. 1998. PMID: 9766105
-
Clinical use of an aerosol-reduction device with an ultrasonic scaler.Compend Contin Educ Dent. 1996 Dec;17(12):1185-93; quiz 1194. Compend Contin Educ Dent. 1996. PMID: 9161132
-
Occupational exposure to endotoxin from contaminated dental unit waterlines.SADJ. 2009 Feb;64(1):8, 10-2, 14. SADJ. 2009. PMID: 19418897 Review.
-
Aerosol and splatter production by focused spray and standard ultrasonic inserts.J Periodontol. 1999 May;70(5):473-7. doi: 10.1902/jop.1999.70.5.473. J Periodontol. 1999. PMID: 10368050
-
Bacterial aerosols in the dental clinic: a review.Int Dent J. 2001 Feb;51(1):39-44. doi: 10.1002/j.1875-595x.2001.tb00816.x. Int Dent J. 2001. PMID: 11326448 Review.
Cited by
-
Spray mist reduction by means of a high-volume evacuation system-Results of an experimental study.PLoS One. 2021 Sep 3;16(9):e0257137. doi: 10.1371/journal.pone.0257137. eCollection 2021. PLoS One. 2021. PMID: 34478480 Free PMC article.
-
Infection Risk of COVID-19 in Dentistry Remains Unknown: A Preliminary Systematic Review.Infect Dis Clin Pract (Baltim Md). 2021 Mar;29(2):e70-e77. doi: 10.1097/IPC.0000000000000939. Epub 2020 Sep 14. Infect Dis Clin Pract (Baltim Md). 2021. PMID: 34191900 Free PMC article. Review.
-
Distribution characteristics of microbial aerosols and optimization of protective methods during ultrasonic scaling procedure.Sci Rep. 2025 Jun 4;15(1):19598. doi: 10.1038/s41598-025-04857-w. Sci Rep. 2025. PMID: 40467899 Free PMC article. Clinical Trial.
-
Risk of Contamination of Different Areas of Dentist's Face During Dental Practices.Int J Prev Med. 2013 May;4(5):611-5. Int J Prev Med. 2013. PMID: 23930175 Free PMC article.
-
The efficacy of an extraoral scavenging device on reduction of splatter contamination during dental aerosol generating procedures: an exploratory study.Br Dent J. 2020 Sep 11:1-10. doi: 10.1038/s41415-020-2112-7. Online ahead of print. Br Dent J. 2020. PMID: 32918060 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical