Flow cytometric measurement of cell cycle kinetics in rat Walker-256 carcinoma following in vivo and in vitro pulse labelling with bromodeoxyuridine
- PMID: 1825629
- DOI: 10.1002/cyto.990120106
Flow cytometric measurement of cell cycle kinetics in rat Walker-256 carcinoma following in vivo and in vitro pulse labelling with bromodeoxyuridine
Abstract
Flow cytometric measurements of total DNA content, cell cycle distribution, and bromodeoxyuridine (BrdUrd) uptake were made in rat Walker-256 carcinoma cells. After both in vivo and in vitro pulse labelling with BrdUrd, Walker-256 tumor cells were stained with propidium iodide (PI) to estimate the total DNA content and a monoclonal antibody against BrdUrd to estimate the relative amount of cells in S phase. BrdUrd-labelled single cell suspensions were harvested at different time intervals to determine the movement of these cells within the cell cycle. To increase BrdUrd uptake, fluorodeoxyuridine (FDU), a thymidine antagonist, was also applied in vivo and in vitro. The results indicated exponential growth characteristics for this tumor between days 5 and 8 after implantation. Tumor doubling times, derived from changes in tumor volume in vivo and from the increase in cell number in vitro were similar. The mean time for DNA synthesis was estimated from the relative movement of BrdUrd-labelled cells towards G2. The percent of cells labelled with BrdUrd and the DNA synthesis time were similar regardless of the mode of BrdUrd administration. This study demonstrates that BrdUrd labelling of rat Walker-256 carcinoma cells in vitro yields kinetic estimates of tumor proliferation during exponential growth similar to those with the administration of BrdUrd in the intact tumor-bearing rat.
Similar articles
-
A method to estimate cell cycle time and growth fraction using bromodeoxyuridine-flow cytometry data from a single sample.BMC Cancer. 2005 Sep 22;5:122. doi: 10.1186/1471-2407-5-122. BMC Cancer. 2005. PMID: 16176590 Free PMC article.
-
A method to measure the duration of DNA synthesis and the potential doubling time from a single sample.Cytometry. 1985 Nov;6(6):620-6. doi: 10.1002/cyto.990060618. Cytometry. 1985. PMID: 4064842
-
Cell kinetics in mouse epidermis studied by bivariate DNA/bromodeoxyuridine and DNA/keratin flow cytometry.Cytometry. 1990;11(2):253-60. doi: 10.1002/cyto.990110206. Cytometry. 1990. PMID: 1690627
-
Cell proliferation: analysis by flow cytometry.Nouv Rev Fr Hematol (1978). 1992;34(4):317-35. Nouv Rev Fr Hematol (1978). 1992. PMID: 1448353 Review.
-
Cell cycle analysis using flow cytometry.Int J Radiat Biol Relat Stud Phys Chem Med. 1986 Feb;49(2):237-55. doi: 10.1080/09553008514552531. Int J Radiat Biol Relat Stud Phys Chem Med. 1986. PMID: 3510993 Review.
Cited by
-
Single-cell template strand sequencing by Strand-seq enables the characterization of individual homologs.Nat Protoc. 2017 Jun;12(6):1151-1176. doi: 10.1038/nprot.2017.029. Epub 2017 May 11. Nat Protoc. 2017. PMID: 28492527
-
Polysaccharopeptides derived from Coriolus versicolor potentiate the S-phase specific cytotoxicity of Camptothecin (CPT) on human leukemia HL-60 cells.Chin Med. 2010 Apr 27;5:16. doi: 10.1186/1749-8546-5-16. Chin Med. 2010. PMID: 20423495 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous