[Corneal topography. Analysis of the corneal surface]
- PMID: 18265992
- DOI: 10.1007/s00347-008-1696-0
[Corneal topography. Analysis of the corneal surface]
Abstract
Various diagnostic procedures have been developed for analyzing the corneal surface. Corneal topographical measurements can be performed by classic Placido disc topographers and tomographers creating three-dimensional corneal models from cross-sectional images. Using a slit scanning system or the Scheimpflug technique additional information about the anterior segment can be obtained. New systems give us a wide range of diagnostic tools. Beside the measurement of the corneal anterior and posterior surfaces and point-to-point-pachymetry they enable analysis of corneal aberrations and measurement of the whole anterior segment, including the anterior chamber and the position of implants, pupil diameter, horizontal white-to-white and the kappa angle. Densitometry, statistical programs for the evaluation of corneal pathology and assistance with intraocular lens calculation following excimer laser treatment are further options available. This article is intended to give an overview of the principles and limitations of the various diagnostic systems.
Similar articles
-
Corneal Topography.2023 Sep 4. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2023 Sep 4. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 36251835 Free Books & Documents.
-
[Scheimpflug and topography systems in ophthalmologic diagnostics].Ophthalmologe. 2008 Sep;105(9):810-7. doi: 10.1007/s00347-008-1821-0. Ophthalmologe. 2008. PMID: 18751984 German.
-
Applications of corneal topography and tomography: a review.Clin Exp Ophthalmol. 2018 Mar;46(2):133-146. doi: 10.1111/ceo.13136. Epub 2018 Jan 11. Clin Exp Ophthalmol. 2018. PMID: 29266624 Review.
-
Cornea and anterior eye assessment with placido-disc keratoscopy, slit scanning evaluation topography and scheimpflug imaging tomography.Indian J Ophthalmol. 2018 Mar;66(3):360-366. doi: 10.4103/ijo.IJO_850_17. Indian J Ophthalmol. 2018. PMID: 29480244 Free PMC article. Review.
-
[Corneal topography and keratoconus diagnostics with Scheimpflug photography].Ophthalmologe. 2014 Oct;111(10):920-6. doi: 10.1007/s00347-013-2962-3. Ophthalmologe. 2014. PMID: 25278345 Review. German.
Cited by
-
[Possibilities for use of Scheimpflug technology in cataract surgery].Ophthalmologe. 2014 Oct;111(10):927-34. doi: 10.1007/s00347-013-2961-4. Ophthalmologe. 2014. PMID: 25278344 Review. German.
-
[Difference and distance between the central and thinnest points of the cornea: impact of refractive state, age and ocular side].Ophthalmologe. 2014 Apr;111(4):339-47. doi: 10.1007/s00347-013-2892-0. Ophthalmologe. 2014. PMID: 23921813 German.
-
Pentacam corneal topography and densitometry features of PCOS patients.BMC Ophthalmol. 2023 Jan 3;23(1):5. doi: 10.1186/s12886-022-02758-4. BMC Ophthalmol. 2023. PMID: 36597084 Free PMC article.
-
Importance of fixation, pupil center, and reference axis in ocular wavefront sensing, videokeratography, and retinal image quality.J Cataract Refract Surg. 2009 Jan;35(1):139-52. doi: 10.1016/j.jcrs.2008.09.014. J Cataract Refract Surg. 2009. PMID: 19101437 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical