Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 May;19(5):519-27.
doi: 10.1111/j.1540-8167.2007.01087.x. Epub 2008 Feb 4.

An acute model for atrial fibrillation arising from a peripheral atrial site: evidence for primary and secondary triggers

Affiliations

An acute model for atrial fibrillation arising from a peripheral atrial site: evidence for primary and secondary triggers

Benjamin J Scherlag et al. J Cardiovasc Electrophysiol. 2008 May.

Abstract

Background: We previously demonstrated that acetylcholine (Ach) injected into cardiac ganglionated plexi (GP) causes pulmonary vein (PV) ectopy initiating atrial fibrillation (AF).

Objective: To determine the effects of Ach applied at non-PV sites.

Methods: Overall, 54 dogs were anesthetized with Na-pentobarbital. A right and left thoracotomy allowed the placement of multielectrode catheters to record from the superior PVs, mid portion of the atrium and the atrial appendages (AA). A monophasic action potential (MAP) was recorded from the AA. Ach (1, 10, 100 mM) was applied sequentially to the AA.

Results: In 19 of 26 animals, Ach 100 mM on the right (n = 15) or left (n = 4) AA induced focal, sustained AF (>or=10 minutes) with rapid regular firing (cycle length = 37 +/- 7 ms) at the AA. A clamp with teeth placed across the AA caused arrest in the AA. However, AF was sustained only when PV sites adjacent to the GP manifested complex fractionated atrial electrograms (CFAE). Clamping the AA prior to Ach (100 mM) application resulted in focal AF arising at the PVs but not at the AA. When a clamp without teeth was applied prior to Ach application, no AF at either AA or PV site could be induced.

Conclusion: Isolation of the focal AF at the AA (primary trigger) by clamping caused cessation of activity in the AA, but AF continued due to secondary triggers arising from PVs. The possible mechanism(s) responsible for these findings are discussed, and various ancillary experiments (n = 28) were added to help elucidate mechanisms.

PubMed Disclaimer

Publication types

MeSH terms