A pyramid approach to subpixel registration based on intensity
- PMID: 18267377
- DOI: 10.1109/83.650848
A pyramid approach to subpixel registration based on intensity
Abstract
We present an automatic subpixel registration algorithm that minimizes the mean square intensity difference between a reference and a test data set, which can be either images (two-dimensional) or volumes (three-dimensional). It uses an explicit spline representation of the images in conjunction with spline processing, and is based on a coarse-to-fine iterative strategy (pyramid approach). The minimization is performed according to a new variation (ML*) of the Marquardt-Levenberg algorithm for nonlinear least-square optimization. The geometric deformation model is a global three-dimensional (3-D) affine transformation that can be optionally restricted to rigid-body motion (rotation and translation), combined with isometric scaling. It also includes an optional adjustment of image contrast differences. We obtain excellent results for the registration of intramodality positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) data. We conclude that the multiresolution refinement strategy is more robust than a comparable single-stage method, being less likely to be trapped into a false local optimum. In addition, our improved version of the Marquardt-Levenberg algorithm is faster.
Similar articles
-
Analytic differential approach for robust registration of rat brain histological images.Microsc Res Tech. 2011 Jun;74(6):523-30. doi: 10.1002/jemt.20942. Epub 2010 Oct 13. Microsc Res Tech. 2011. PMID: 20945464
-
Real-time affine global motion estimation using phase correlation and its application for digital image stabilization.IEEE Trans Image Process. 2011 Dec;20(12):3406-18. doi: 10.1109/TIP.2011.2156420. Epub 2011 May 19. IEEE Trans Image Process. 2011. PMID: 21606029
-
Robust image registration for functional magnetic resonance imaging of the brain.Med Biol Eng Comput. 2001 Sep;39(5):517-24. doi: 10.1007/BF02345141. Med Biol Eng Comput. 2001. PMID: 11712647
-
Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.J Nucl Med. 2003 Jul;44(7):1156-67. J Nucl Med. 2003. PMID: 12843232
-
A Practical Approach Based on Analytic Deformable Algorithm for Scenic Image Registration.PLoS One. 2013 Jun 21;8(6):e66656. doi: 10.1371/journal.pone.0066656. Print 2013. PLoS One. 2013. PMID: 23805257 Free PMC article.
Cited by
-
Dynamic relocalization of cytosolic type III secretion system components prevents premature protein secretion at low external pH.Nat Commun. 2021 Mar 12;12(1):1625. doi: 10.1038/s41467-021-21863-4. Nat Commun. 2021. PMID: 33712575 Free PMC article.
-
High-content imaging with micropatterned multiwell plates reveals influence of cell geometry and cytoskeleton on chromatin dynamics.Biotechnol J. 2015 Oct;10(10):1555-67. doi: 10.1002/biot.201400756. Epub 2015 Jul 14. Biotechnol J. 2015. PMID: 26097126 Free PMC article.
-
Disruption of Plasmodium falciparum kinetochore proteins destabilises the nexus between the centrosome equivalent and the mitotic apparatus.Nat Commun. 2024 Jul 10;15(1):5794. doi: 10.1038/s41467-024-50167-6. Nat Commun. 2024. PMID: 38987258 Free PMC article.
-
Anesthetics fragment hippocampal network activity, alter spine dynamics, and affect memory consolidation.PLoS Biol. 2021 Apr 1;19(4):e3001146. doi: 10.1371/journal.pbio.3001146. eCollection 2021 Apr. PLoS Biol. 2021. PMID: 33793545 Free PMC article.
-
Calcium imaging in freely-moving mice during electrical stimulation of deep brain structures.J Neural Eng. 2020 Sep 11:10.1088/1741-2552/abb7a4. doi: 10.1088/1741-2552/abb7a4. Online ahead of print. J Neural Eng. 2020. PMID: 32916665 Free PMC article.
LinkOut - more resources
Full Text Sources
Other Literature Sources