Functional systolic anterior motion of the mitral valve due to accessory chordae
- PMID: 18268432
- DOI: 10.2459/JCM.0b013e3280c852b2
Functional systolic anterior motion of the mitral valve due to accessory chordae
Abstract
Accessory mitral valve tissue is an uncommon finding, usually associated with other congenital cardiac malformations and diagnosed during childhood. We present the case of a 70-year-old patient referred to our hospital for aortic valve and ascending aorta replacement. At preoperative examination, no evidence of mitral valve structural abnormalities was detected. Anaesthesia induction was complicated by sudden haemodynamic impairment. Intraoperative transoesophageal echocardiography showed two anomalous mitral chordae. The presence of abnormal mitral tissue also allowed to assess the mechanism of unexpected haemodynamic worsening: anomalous chordae caused anterior displacement of the anterior mitral leaflet, resulting in left ventricular outflow tract obstruction and mitral regurgitation. Medical therapy was instituted and the planned surgical approach was modified according to the new anatomy observed at echocardiographic examination. A valve-sparing technique was successfully applied. This case provides a good example of the diagnostic usefulness of routine intraoperative transoesophageal echocardiography, especially when facing unexpected findings. It also shows how transoesophageal echocardiography may help guide medical and surgical treatment.
Similar articles
-
Apical ballooning syndrome complicated by acute severe mitral regurgitation with left ventricular outflow obstruction--case report.J Cardiothorac Surg. 2007 Feb 21;2:14. doi: 10.1186/1749-8090-2-14. J Cardiothorac Surg. 2007. PMID: 17313686 Free PMC article.
-
[Mitral regurgitation due to abnormal reinsertion of chordae tendineae (looping) of the posterior mitral leaflet: clinical and echocardiographic features].J Cardiogr. 1986 Dec;16(4):919-28. J Cardiogr. 1986. PMID: 3429908 Japanese.
-
[Left ventricular outflow tract obstruction caused by accessory mitral valve tissue].Arch Inst Cardiol Mex. 1996 Jan-Feb;66(1):44-50. Arch Inst Cardiol Mex. 1996. PMID: 8768621 Spanish.
-
Fibrous cyst of the chordae tendineae of the mitral valve: echocardiographic appearance and literature review.Echocardiography. 2015 Jan;32(1):174-7. doi: 10.1111/echo.12750. Epub 2014 Sep 24. Echocardiography. 2015. PMID: 25251665 Review.
-
Accessory mitral valve tissue: a case report and an updated review of literature.J Card Surg. 2008 Nov-Dec;23(6):769-72. doi: 10.1111/j.1540-8191.2008.00633.x. J Card Surg. 2008. PMID: 19017009 Review.
Cited by
-
Accessory mitral valve without left ventricular outflow tract obstruction in an adult.Tex Heart Inst J. 2008;35(3):324-6. Tex Heart Inst J. 2008. PMID: 18941599 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources