A unique failure mechanism of a constrained total hip arthroplasty: a brief review of the literature
- PMID: 18280427
- DOI: 10.1016/j.arth.2006.12.099
A unique failure mechanism of a constrained total hip arthroplasty: a brief review of the literature
Abstract
Constrained acetabular systems are successful in achieving stability in patients with recurrent dislocations, abductor deficiency, or where a source of instability cannot be determined. We report on one patient with 2 dissociations of a tripolar constrained acetabular liner caused by impingement when the patient exceeded the allowed range of motion. The inner liner dissociated from the outer liner, whereas the reinforcing ring remained intact and in place. Despite an extensive literature search, we were unable to find any other published reports concerning this specific mode of failure for this constrained liner. Surgeons should be aware that constrained liners are not infallible and have limitations to range of motion. Maximizing the size of the femoral head may reduce the risk of this mode of failure.
Similar articles
-
Failure mechanism of a constrained liner: a case report.Acta Orthop Belg. 2012 Feb;78(1):129-33. Acta Orthop Belg. 2012. PMID: 22523941
-
Failure mechanisms and closed reduction of a constrained tripolar acetabular liner.J Arthroplasty. 2009 Feb;24(2):322.e5-11. doi: 10.1016/j.arth.2008.01.002. Epub 2008 Dec 9. J Arthroplasty. 2009. PMID: 19081224
-
High failure rate of a constrained acetabular liner in revision total hip arthroplasty.J Arthroplasty. 2005 Oct;20(7 Suppl 3):103-7. doi: 10.1016/j.arth.2005.05.005. J Arthroplasty. 2005. PMID: 16214010
-
Cementing constrained acetabular liners in revision hip replacement: clinical and laboratory observations.Instr Course Lect. 2004;53:131-40. Instr Course Lect. 2004. PMID: 15116607 Review.
-
Constrained components for the unstable hip following total hip arthroplasty: a literature review.Int Orthop. 2007 Jun;31(3):273-7. doi: 10.1007/s00264-006-0191-y. Epub 2006 Aug 23. Int Orthop. 2007. PMID: 16927089 Free PMC article. Review.
Cited by
-
Catastrophic failure of tripolar constrained liners due to backside wear: a novel failure mode.Arthroplast Today. 2018 May 18;4(3):270-274. doi: 10.1016/j.artd.2018.04.002. eCollection 2018 Sep. Arthroplast Today. 2018. PMID: 30186903 Free PMC article.
-
Implant survival of 662 dual-mobility cups and 727 constrained liners in primary THA: small femoral head size increases the cumulative incidence of revision.Acta Orthop. 2021 Dec;92(6):658-664. doi: 10.1080/17453674.2021.1939597. Epub 2021 Jul 9. Acta Orthop. 2021. PMID: 34238130 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical