Highly cross-linked polyethylene bearing surfaces in total hip arthroplasty
- PMID: 18284901
Highly cross-linked polyethylene bearing surfaces in total hip arthroplasty
Abstract
Polyethylene wear-induced osteolysis is the most significant primary factor limiting the life span of total joint arthroplasty. To reduce ultra-high-molecular-weight polyethylene (UHMWPE) particulate wear debris, highly cross-linked polyethylene (HXPE) bearings have been introduced in total hip arthroplasty (THA). In vitro hip simulator wear studies with HXPE have demonstrated a decrease in volumetric wear at the hip by 42% to 100% when compared with conventional metal-on-polyethylene bearings. Early to intermediate clinical results suggest that the in vivo wear properties of HXPE products are superior to those of conventional UHMWPE. Second-generation HXPE materials that utilize alternate cross-linking and free radical quenching techniques have been developed and propose to further minimize wear and oxidation.
Similar articles
-
The basis for a second-generation highly cross-linked UHMWPE.Clin Orthop Relat Res. 2006 Dec;453:265-71. doi: 10.1097/01.blo.0000238856.61862.7d. Clin Orthop Relat Res. 2006. PMID: 17016228
-
Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.J Orthop Res. 1999 Mar;17(2):157-67. doi: 10.1002/jor.1100170203. J Orthop Res. 1999. PMID: 10221831
-
Alternative materials to improve total hip replacement tribology.Acta Orthop Scand. 2003 Aug;74(4):380-8. doi: 10.1080/00016470310017668. Acta Orthop Scand. 2003. PMID: 14521286 Review.
-
Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.Biomaterials. 2005 Jun;26(16):3259-67. doi: 10.1016/j.biomaterials.2004.07.070. Biomaterials. 2005. PMID: 15603821
-
Implant wear mechanisms--basic approach.Biomed Mater. 2008 Dec;3(4):042001. doi: 10.1088/1748-6041/3/4/042001. Epub 2008 Sep 25. Biomed Mater. 2008. PMID: 18824778 Review.
Cited by
-
Characterization of topographical effects on macrophage behavior in a foreign body response model.Biomaterials. 2010 May;31(13):3479-91. doi: 10.1016/j.biomaterials.2010.01.074. Epub 2010 Feb 6. Biomaterials. 2010. PMID: 20138663 Free PMC article.
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem.J Bone Joint Surg Am. 2012 Oct 17;94(20):1877-85. doi: 10.2106/JBJS.J.01507. J Bone Joint Surg Am. 2012. PMID: 23079880 Free PMC article.
-
UHMWPE for arthroplasty: past or future?J Orthop Traumatol. 2009 Mar;10(1):1-8. doi: 10.1007/s10195-008-0038-y. Epub 2008 Dec 24. J Orthop Traumatol. 2009. PMID: 19384628 Free PMC article.
-
Polyethylene and metal wear particles: characteristics and biological effects.Semin Immunopathol. 2011 May;33(3):257-71. doi: 10.1007/s00281-011-0242-3. Epub 2011 Jan 26. Semin Immunopathol. 2011. PMID: 21267569 Review.
-
Mediators of the inflammatory response to joint replacement devices.Nat Rev Rheumatol. 2011 Sep 6;7(10):600-8. doi: 10.1038/nrrheum.2011.128. Nat Rev Rheumatol. 2011. PMID: 21894210 Review.