Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jan;19(1):46-54.
doi: 10.1016/j.jasms.2007.10.015.

Automated charge state determination of complex isotope-resolved mass spectra by peak-target Fourier transform

Affiliations

Automated charge state determination of complex isotope-resolved mass spectra by peak-target Fourier transform

Li Chen et al. J Am Soc Mass Spectrom. 2008 Jan.

Abstract

This study describes a new algorithm for charge state determination of complex isotope-resolved mass spectra. This algorithm is based on peak-target Fourier transform (PTFT) of isotope packets. It is modified from the widely used Fourier transform method because Fourier transform may give ambiguous charge state assignment for low signal-to-noise ratio (S/N) or overlapping isotopic clusters. The PTFT algorithm applies a novel "folding" strategy to enhance peaks that are symmetrically spaced about the targeted peak before applying the FT. The "folding" strategy multiplies each point to the high-m/z side of the targeted peak by its counterpart on the low-m/z side. A Fourier transform of this "folded" spectrum is thus simplified, emphasizing the charge state of the "chosen" ion, whereas ions of other charge states contribute less to the transformed data. An intensity-dependent technique is also proposed for charge state determination from frequency signals. The performance of PTFT is demonstrated using experimental electrospray ionization Fourier transform ion cyclotron resonance mass spectra. The results show that PTFT is robust for charge state determination of low S/N and overlapping isotopic clusters, and also useful for manual verification of potential hidden isotopic clusters that may be missed by the current analysis algorithms, i.e., AID-MS or THRASH.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Anal Chem. 2003 Apr 1;75(7):1599-603 - PubMed
    1. Anal Chem. 2006 Apr 1;78(7):2113-20 - PubMed
    1. Chem Rev. 2001 Feb;101(2):269-95 - PubMed
    1. J Am Soc Mass Spectrom. 2001 Nov;12(11):1153-62 - PubMed
    1. J Am Soc Mass Spectrom. 1995 Apr;6(4):229-33 - PubMed

Publication types

LinkOut - more resources