Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Feb;24(2):178-87.
doi: 10.3928/1081597X-20080201-09.

Experimental assessment of corneal anisotropy

Affiliations

Experimental assessment of corneal anisotropy

Ahmed Elsheikh et al. J Refract Surg. 2008 Feb.

Abstract

Purpose: To determine the variation of corneal biomechanical properties with anatomical orientation.

Methods: Strip specimens extracted from fresh porcine corneas were tested under uniaxial tension with strain rates representing static and dynamic loading conditions. The specimens were extracted from the vertical, horizontal, and 45 degrees diagonal directions. The load elongation results were used to derive the stress-strain behavior of each specimen. The average behavior for specimens taken in each anatomical direction was determined along with the effect of strain rate. Specimens from a small number of human corneas were included in the study to verify the findings.

Results: Specimens extracted from the vertical direction of porcine and human corneas demonstrated the highest strength (fracture stress) followed by horizontal then diagonal specimens. Vertical specimens were 10% to 20% stronger than horizontal specimens in porcine and human corneas. At low strain rates (1%/min), vertical specimens displayed similar stiffness (resistance to deformation) to horizontal specimens but greater stiffness than diagonal specimens. On increasing the strain rate to 500%/min, the stiffness behavior matched that of strength with vertical specimens being 10% to 20% stiffer than horizontal specimens in porcine and human corneas.

Conclusions: The corneal anisotropic behavior is compatible with the preferential orientation of stromal fibrils in the vertical and horizontal directions. Quantifying the effect of this nonuniform fibril organization on corneal anisotropic behavior will be useful in developing numerical models of the cornea for applications where its integrity is compromised such as in simulating refractive surgery procedures.

PubMed Disclaimer

LinkOut - more resources