Variability of coronary calcium scores throughout the cardiac cycle: implications for the appropriate use of electrocardiogram-dose modulation with retrospectively gated computed tomography
- PMID: 18301315
- DOI: 10.1097/RLI.0b013e31815cdd56
Variability of coronary calcium scores throughout the cardiac cycle: implications for the appropriate use of electrocardiogram-dose modulation with retrospectively gated computed tomography
Abstract
Objective: To study how much the calcium scores at various phases throughout the cardiac cycle deviate from the score in the most motionless phase during retrospectively electrocardiogram (ECG)-gated multidetector row computed tomography (MDCT) of the heart and to evaluate how to optimize ECG-based tube current modulation so that errors in calcium scoring can be minimized while dose savings can be maximized.
Materials and methods: In 73 subjects with known or suspected coronary artery disease we performed retrospectively ECG-gated 64-detector row computed tomography for calcium scoring. Four subjects were excluded after scanning because of breathing artifacts or lack of coronary calcification. The scans of 69 subjects (46 men, mean age 62 +/- 6 years) were used for further analysis. Heart rate during the scan was recorded. In each patient, calcium scoring [Agatston score (AS), mass score (MS), and volume score, (VS)] was performed on 10 data sets reconstructed at 10%-intervals throughout the cardiac cycle. The most motionless phase was subjectively determined and used as the reference phase. For the score in each phase, deviation from the score in the reference phase was determined. An ECG-simulator was used to determine the amount of dose saving while scanning with dose modulation and applying diagnostic dose during 1 or several phases.
Results: Mean heart rate was 63 (+/-13) beats per minute (bpm). In 51% of patients the reference phase was the 70% phase. Using the calcium score in the 70% phase (mid-diastole) instead of the reference at heart rates below 70 bpm would have induced a median score deviation of 0% [interquartile range: 0%-6% (AS, MS, and VS)] and using the calcium score in the 40% phase (end-systole) at heart rates > or =70 bpm would also have induced a median score deviation of 0% [interquartile range: 0%-7% (AS), 0%-5% (MS), and 0%-3% (VS)]. Errors in calcium scores of more than 10% occur in around 10% of subjects for all 3 scoring algorithms. Dose savings increased with lower heart rates and shorter application of diagnostic dose.
Conclusions: The optimum phases for dose modulation are 70% (mid-diastole) at heart rates below 70 bpm and 40% (end-systole) at heart rates above 70 bpm. Under these conditions dose saving is maximum and a median error of 0% is found for the various calcium scoring techniques with score errors of more than 10% in around 10% of subjects.
Similar articles
-
Optimal cardiac phase for coronary artery calcium scoring on single-source 64-MDCT scanner: least interscan variability and least motion artifacts.AJR Am J Roentgenol. 2008 Jun;190(6):1561-8. doi: 10.2214/AJR.07.3120. AJR Am J Roentgenol. 2008. PMID: 18492907
-
Evaluation of attenuation-based tube current control in coronary artery calcium scoring on prospective ECG-triggered 64-detector CT.Acad Radiol. 2009 Oct;16(10):1231-40. doi: 10.1016/j.acra.2009.04.008. Epub 2009 Jun 9. Acad Radiol. 2009. PMID: 19515586
-
The influence of heart rate, slice thickness, and calcification density on calcium scores using 64-slice multidetector computed tomography: a systematic phantom study.Invest Radiol. 2007 Dec;42(12):848-55. doi: 10.1097/RLI.0b013e318154c549. Invest Radiol. 2007. PMID: 18007157
-
Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study.Radiology. 2005 Aug;236(2):477-84. doi: 10.1148/radiol.2362040513. Epub 2005 Jun 21. Radiology. 2005. PMID: 15972340 Review.
-
Optimizing coronary artery imaging in patients with atrial fibrillation with ECG-gated 64-MDCT.AJR Am J Roentgenol. 2007 Jul;189(1):W50-1. doi: 10.2214/AJR.07.0151. AJR Am J Roentgenol. 2007. PMID: 17579139 Review. No abstract available.
Cited by
-
Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study.Eur Radiol. 2021 Dec;31(12):9211-9220. doi: 10.1007/s00330-021-08076-5. Epub 2021 May 28. Eur Radiol. 2021. PMID: 34050386 Free PMC article.
-
Reproducibility of coronary artery calcium measurements using 0.8-mm-thickness 256-slice coronary CT.Jpn J Radiol. 2014 Dec;32(12):677-84. doi: 10.1007/s11604-014-0364-3. Epub 2014 Oct 3. Jpn J Radiol. 2014. PMID: 25277791
-
Influence of heart rate on coronary calcium scores: a multi-manufacturer phantom study.Int J Cardiovasc Imaging. 2018 Jun;34(6):959-966. doi: 10.1007/s10554-017-1293-x. Epub 2017 Dec 28. Int J Cardiovasc Imaging. 2018. PMID: 29285727
-
Automatic detection and quantification of the Agatston coronary artery calcium score on contrast computed tomography angiography.Int J Cardiovasc Imaging. 2015 Jan;31(1):151-61. doi: 10.1007/s10554-014-0519-4. Epub 2014 Aug 27. Int J Cardiovasc Imaging. 2015. PMID: 25159031
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials