Ultra sensitive sensor with enhanced dynamic range for high speed detection of multi-color fluorescence radiation
- PMID: 18304800
- DOI: 10.1016/j.bios.2008.01.015
Ultra sensitive sensor with enhanced dynamic range for high speed detection of multi-color fluorescence radiation
Abstract
This paper describes design of the new ultra sensitive sensor system for fluorescence detection applications. System comprises two units: optical spectra separation unit and detection unit. Optical unit of the sensor performs spatial spectra separation of signal from the laser excited fluorescence, and resulting spectra is collected in the detection part of the system. Optical part is built using diffraction grating as spectra separation element. Detection part comprises 32-channel photomultiplier tube working in single photon counting mode with our 32-channel amplifier. Using single photon detection technique and specific signal processing algorithms for collected data, the proposed system allows to achieve unique combination of characteristics--high sensitivity, high detection speed and wide linearity dynamic range comparing to existing commercial instruments. DNA sequencing experiments with new sensor as detection device, and using two types of lasers (Ar-ion and Nd-YAG) were carried out, yielding sequencing traces which have quality factor of 20 for read lengths as long as 650 base pairs.
Similar articles
-
CCD based fiber-optic spectrometer detection.Methods Mol Biol. 2009;503:435-45. doi: 10.1007/978-1-60327-567-5_25. Methods Mol Biol. 2009. PMID: 19151957
-
Detection of fluorescence generated in microfluidic channel using in-fiber grooves and in-fiber microchannel sensors.Methods Mol Biol. 2009;503:403-22. doi: 10.1007/978-1-60327-567-5_23. Methods Mol Biol. 2009. PMID: 19151955
-
Detection of trophic factor activated signaling molecules in cells by a compact fiber-optic sensor.Biosens Bioelectron. 2004 Sep 15;20(2):345-9. doi: 10.1016/j.bios.2004.02.004. Biosens Bioelectron. 2004. PMID: 15308240
-
Optical system design for biosensors based on CCD detection.Methods Mol Biol. 2009;503:239-58. doi: 10.1007/978-1-60327-567-5_13. Methods Mol Biol. 2009. PMID: 19151945 Review.
-
Evanescent wave fluorescence biosensors.Biosens Bioelectron. 2005 Jun 15;20(12):2470-87. doi: 10.1016/j.bios.2004.10.026. Epub 2004 Dec 8. Biosens Bioelectron. 2005. PMID: 15854820 Review.
Cited by
-
Enhancing the Linear Dynamic Range in Multi-Channel Single Photon Detector beyond 7OD.IEEE Sens J. 2015 Dec;15(12):7081-7086. doi: 10.1109/JSEN.2015.2471277. Epub 2015 Aug 21. IEEE Sens J. 2015. PMID: 27087788 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials