Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2008;26(3):226-30.
doi: 10.1159/000118846. Epub 2008 Feb 28.

Comparison of two dialysers (AN69ST vs. FX100) for heparin-free dialysis in patients with oral anticoagulation

Affiliations
Randomized Controlled Trial

Comparison of two dialysers (AN69ST vs. FX100) for heparin-free dialysis in patients with oral anticoagulation

Katharina Kodras et al. Blood Purif. 2008.

Abstract

Background: Heparin-free dialysis (HFD), i.e. only priming of the dialyser and no systemic heparinization, might reduce the risk of bleeding in dialysis patients receiving oral anticoagulation. The efficacy of HFD with two different membranes [polyacrylonitrile (AN69ST) vs. polysulphone (FX100)] was therefore investigated.

Methods: In a crossover design, 10 patients were treated with either membrane for 1 week (total 30 sessions). Weekly Kt/V and urea reduction rate (URR) were measured and thrombus formation evaluated by measurement of D-dimer and inspection of the air traps and dialyser.

Results: Change of clotting markers was similar with both membranes. Complete thrombosis occurred in 3/30 patients with the AN69ST and in 1/30 patients with the FX100 membrane. Kt/V did not differ between the groups, but the URR was slightly higher with the FX100.

Conclusion: HFD prevents dialyser occlusion in the majority of patients treated with oral anticoagulants. Both polysulphone and polyacrylonitrile membranes seem to be equally effective.