Comparative study of the kinetics of the renal tracers 99Tcm-MAG3 and 131I-hippuran
- PMID: 1830943
- DOI: 10.1097/00006231-199106000-00007
Comparative study of the kinetics of the renal tracers 99Tcm-MAG3 and 131I-hippuran
Abstract
Serial measurements of plasma activity, plasma protein binding and urine excretion were obtained in order to study 99Tcm-MAG3 (MAG) and 131I-Hippuran (OIH) kinetics after simultaneous injection of both tracers in 21 patients with various renal diseases. Results were compared on the basis of a compartmental model, calculating the rate constants as well as the clearance and volume of distribution. Protein binding was calculated in 10 patients (mean: MAG = 54.7%, OIH = 33.8%). The dependence of time, tracer and patient factors was shown by ANOVA. Time was independent, with tracer and patient factors and their interaction being significant. The mean value of the renal excretion constant was equal for the two tracers (k12 = 0.052 min-1). The clearance values were found to be highly correlated (r = 0.982) with a ratio of 0.57 between them. The volumes of distribution in litres were 4.1 (MAG) and 7.0 (OIH). One-hour urine excretion was nearly the same for both tracers (MAG: 64%, OIH: 63% of the injected dose).
Similar articles
-
Clinical comparison of technetium-99m-EC, technetium-99m-MAG3 and iodine-131-OIH in renal disorders.J Nucl Med. 1995 Feb;36(2):224-8. J Nucl Med. 1995. PMID: 7830118
-
Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers.J Nucl Med. 1986 Jun;27(6):795-803. J Nucl Med. 1986. PMID: 2940350
-
Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats.J Nucl Med. 1987 Dec;28(12):1881-7. J Nucl Med. 1987. PMID: 2960790
-
Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99mTc renal tubular function agent.Semin Nucl Med. 1992 Apr;22(2):61-73. doi: 10.1016/s0001-2998(05)80082-0. Semin Nucl Med. 1992. PMID: 1534184 Review.
-
99mTc renal tubular function agents: current status.Semin Nucl Med. 1990 Jan;20(1):28-40. doi: 10.1016/s0001-2998(05)80174-6. Semin Nucl Med. 1990. PMID: 2136959 Review.
Cited by
-
Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate.Eur J Nucl Med. 1995 Dec;22(12):1379-84. doi: 10.1007/BF01791145. Eur J Nucl Med. 1995. PMID: 8586082
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous