Comparative Study
. 2008 Aug;12(4):379-83.
doi: 10.1007/s10029-008-0351-7. Epub 2008 Feb 29.

Ventralex mesh in umbilical/epigastric hernia repairs: clinical outcomes and complications

Affiliations
Comparative Study

Ventralex mesh in umbilical/epigastric hernia repairs: clinical outcomes and complications

D F Martin et al. Hernia. 2008 Aug.

Abstract

Background: Umbilical and epigastric hernias have historically been repaired without mesh resulting in recurrence rates in some series of up to 40%. Recent data suggests mesh repair of these hernias may decrease recurrent hernia rates. Ideal placement of the mesh is behind the defect, which is difficult to do without a large incision in these hernias unless done laparoscopically. The Ventralex hernia patch is a composite PTFE/polypropylene patch allowing intraperitoneal placement behind the hernia defect through a small incision, and without the cost of laparoscopy. To date, only one study exists evaluating this new prosthesis.

Methods: This study is a retrospective chart review of all umbilical and epigastric hernias repaired with the Ventralex hernia patch by a single surgeon. Patient characteristics and operative and post-operative data were collected. Hernia recurrence is the primary outcome. Secondary outcomes include complication rates.

Results: Eighty-eight patients from 2003-2006 were evaluated. The population included patients aged 25-86 (mean 52) with nineteen females (22%). The average BMI was 32 (range 18-68). Eighteen patients were smokers, five patients were diabetic, and two patients were chronic steroid users. The size of patches used were small (72%), medium (27%), and unknown (1%). Average operating room time was 52 min (range 19-194). The different types of hernias repaired were umbilical (68%), epigastric (30%), and incisional (2%). Follow-up visits ranged from 8 days to 3.1 years in all but five patients (6%). No hernia recurrences were found in follow-up. Complications included two patients (2.2%) with mesh infection requiring removal of the patch, one patient with post-operative urinary retention, and seroma formation in another patient.

Conclusions: The composite PTFE/polypropylene hernia patch is effective in preventing hernia recurrence in umbilical, epigastric, and small ventral hernia repairs and can be accomplished with a low rate of complications.

PubMed Disclaimer

References

    1. Br J Surg. 2001 Oct;88(10):1321-3 - PubMed
    1. Ann Surg. 2004 Oct;240(4):578-83; discussion 583-5 - PubMed
    1. Hernia. 2006 Oct;10(5):409-13 - PubMed
    1. Surg Gynecol Obstet. 1993 Mar;176(3):228-34 - PubMed