Laboratory-based X-ray phase-contrast imaging technique for material and medical science applications
- PMID: 18313312
- DOI: 10.1016/j.apradiso.2007.12.008
Laboratory-based X-ray phase-contrast imaging technique for material and medical science applications
Abstract
In-line X-ray phase-contrast imaging technique is an emerging method for the study of materials such as carbon fibers, carbon composite materials, polymers, etc. Similarly this technique is also well suited for the imaging of soft materials such as tissues, distinguishing between tumor and normal tissue. These represent the class of materials for which X-ray attenuation cross-section is very small. Thus this method promises a far better contrast for low X-ray absorbing substances than the conventional radiography method. We have set up an experimental facility using a combination of X-ray CCD detector and a microfocus X-ray source. This facility is dedicated to micro-imaging experiments such as microtomography and high-resolution phase-contrast experiments. In this paper, the results of X-ray phase-contrast imaging experiments are described.
Similar articles
-
Characterization of pyrocarbon coated materials using laboratory based x-ray phase contrast imaging technique.Rev Sci Instrum. 2007 Aug;78(8):083703. doi: 10.1063/1.2772780. Rev Sci Instrum. 2007. PMID: 17764325
-
X-ray imaging of various biological samples using a phase-contrast hard X-ray microscope.Microsc Res Tech. 2008 Sep;71(9):639-43. doi: 10.1002/jemt.20601. Microsc Res Tech. 2008. PMID: 18454474
-
Curved optics for x-ray phase contrast imaging by synchrotron radiation.Phys Med Biol. 2001 Apr;46(4):967-74. Phys Med Biol. 2001. PMID: 11324971
-
[A powerful tool for study of sperm--soft X-ray microscopy].Zhonghua Nan Ke Xue. 2003 Apr;9(2):124-8. Zhonghua Nan Ke Xue. 2003. PMID: 12749134 Review. Chinese.
-
Development of phase-contrast X-ray imaging techniques and potential medical applications.Phys Med. 2008 Sep;24(3):129-48. doi: 10.1016/j.ejmp.2008.05.006. Epub 2008 Jul 7. Phys Med. 2008. PMID: 18602852 Review.
Cited by
-
Feasibility testing of a pre-clinical coded aperture phase contrast imaging configuration using a simple fast Monte Carlo simulator.Biomed Opt Express. 2013 Dec 4;5(1):93-105. doi: 10.1364/BOE.5.000093. eCollection 2013 Dec 4. Biomed Opt Express. 2013. PMID: 24466479 Free PMC article.
-
Realistic wave-optics simulation of X-ray phase-contrast imaging at a human scale.Sci Rep. 2015 Jul 14;5:12011. doi: 10.1038/srep12011. Sci Rep. 2015. PMID: 26169570 Free PMC article.
-
Phase-contrast imaging with a compact x-ray light source: system design.J Med Imaging (Bellingham). 2017 Oct;4(4):043503. doi: 10.1117/1.JMI.4.4.043503. Epub 2017 Nov 23. J Med Imaging (Bellingham). 2017. PMID: 29201939 Free PMC article.
-
In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography.PLoS One. 2015 Aug 21;10(8):e0135654. doi: 10.1371/journal.pone.0135654. eCollection 2015. PLoS One. 2015. PMID: 26295713 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical