Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients

Affiliations
Comparative Study

Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients

Jochem W H Wolthaus et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: To discuss planning target volumes (PTVs) based on internal target volume (PTVITV), exhale-gated radiotherapy (PTVGating), and a new proposed midposition (PTVMidP; time-weighted mean tumor position) and compare them with the conventional free-breathing CT scan PTV (PTVConv).

Methods and materials: Respiratory motion induces systematic and random geometric uncertainties. Their contribution to the clinical target volume (CTV)-to-PTV margins differs for each PTV approach. The uncertainty margins were calculated using a dose-probability-based margin recipe (based on patient statistics). Tumor motion in four-dimensional CT scans was determined using a local rigid registration of the tumor. Geometric uncertainties for interfractional setup errors and tumor baseline variation were included. For PTVGating, the residual motion within a 30% gating (time) window was determined. The concepts were evaluated in terms of required CTV-to-PTV margin and PTV volume for 45 patients.

Results: Over the patient group, the PTVITV was on average larger (+6%) and the PTVGating and PTVMidP smaller (-10%) than the PTVConv using an off-line (bony anatomy) setup correction protocol. With an on-line (soft tissue) protocol the differences in PTV compared with PTVConv were +33%, -4%, and 0, respectively.

Conclusions: The internal target volume method resulted in a significantly larger PTV than conventional CT scanning. The exhale-gated and mid-position approaches were comparable in terms of PTV. However, mid-position (or mid-ventilation) is easier to use in the clinic because it only affects the planning part of treatment and not the delivery.