Abstract
Dynamic renal scintigraphy using technetium-99m mercaptoacetylglycylglycylglycine (MAG3) has been described in adults, and clearance values have been established using multiple plasma samples. This study of renal clearance has compared two fundamentally different gamma camera techniques (both of which require a single blood sample) with the multiple blood sampling technique in children (n = 30). Results show that a 40-min dynamic 99mTc-MAG3 renal scintigram coupled with a single plasma sample will allow analysis of the data so that clearance values, which are similar to those from multiple plasma samples, may be calculated. The curve generated from the cardiac region of interest (ROI) provided clearances values that had a high correlation coefficient (0.939-0.951) compared to the multiple-plasma sample technique immaterial of the timing of the blood sample. The renal uptake method of clearance had a lower correlation coefficient (0.89-0.92), which varied with the timing of the blood sample compared to the multiple-plasma sampling technique. This study has demonstrated that an extended gamma camera acquisition coupled with a single-plasma sample may be used for quantitative renal function studies using 99mTc-MAG3.
Similar articles
-
Prospective validation of a single sample technique to determine technetium-99m-MAG3 clearance.J Nucl Med. 1992 Sep;33(9):1620-2. J Nucl Med. 1992. PMID: 1387682
-
[A comparison of different methods of calculating clearances using 99mTc-mercaptoacetyltriglycine and 123I- or 131I-ortho-iodohippuric acid].Nuklearmedizin. 1990 Jun;29(3):93-100. Nuklearmedizin. 1990. PMID: 2144045 German.
-
[A comparison of two algorithms for determining renal whole body clearance following simultaneous acquisition with a partially shielded whole-body counter and a gamma camera].Nuklearmedizin. 1990 Jun;29(3):101-8. Nuklearmedizin. 1990. PMID: 2144044 German.
-
Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99mTc renal tubular function agent.Semin Nucl Med. 1992 Apr;22(2):61-73. doi: 10.1016/s0001-2998(05)80082-0. Semin Nucl Med. 1992. PMID: 1534184 Review.
-
Radionuclide renal studies.Curr Opin Radiol. 1990 Dec;2(6):834-43. Curr Opin Radiol. 1990. PMID: 2149277 Review. No abstract available.
Cited by
-
A new principle to normalize plasma concentrations allowing single-sample clearance determinations in both children and adults.Eur J Nucl Med. 1992;19(7):511-6. doi: 10.1007/BF00185857. Eur J Nucl Med. 1992. PMID: 1386574
-
Effect of renal maturation on the clearance of technetium-99m mercaptoacetyltriglycine.Eur J Nucl Med. 1994 Dec;21(12):1333-7. doi: 10.1007/BF02426698. Eur J Nucl Med. 1994. PMID: 7875172
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources