Multicenter Study
. 2008 Mar;90(2):123-6.
doi: 10.1308/003588408X261627.

D-Dimer in the diagnosis of deep vein thrombosis following total hip and knee replacement: a prospective study

Affiliations
Multicenter Study

D-Dimer in the diagnosis of deep vein thrombosis following total hip and knee replacement: a prospective study

A Rafee et al. Ann R Coll Surg Engl. 2008 Mar.

Abstract

Introduction: The merit of using D-dimer estimations in patients following total hip and knee replacement has been previously questioned. A survey of radiology protocols in 70 hospitals ascertained that the test continues to be mandatory in 51 prior to formal radiological investigation of suspected deep vein thrombosis (DVT) in this patient population.

Patients and methods: In this study, D-dimer levels were measured pre-operatively and during the first 7 days following primary total hip and knee replacement to estimate the range of normal values in these patients.

Results: All 78 patients were ultrasonographically shown to be clear of DVT. D-Dimer levels were significantly raised in all patients at all measurements during the first week. Levels after total knee replacement were higher than after total hip replacement. Comparison was made with an age-matched group who had a proven DVT. There was no difference in D-dimer levels between patients with or without a DVT.

Conclusions: The use of this test in this patient group is a waste of resource and merely delays appropriate radiological investigation and treatment.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Mean D-dimer levels pre- and post-surgery.

Comment in

Similar articles

Cited by

References

    1. Gaffney PJ, Edgell T, Creighton-Kempsford LJ, Wheeler S, Tarelli E. Fibrin degradation product (FnDP) assays: analysis of standardization issues and target antigens in plasma. Br J Haematol. 1995;90:187–94. - PubMed
    1. Lip GYH, Lowe GDO. Fibrin D-dimer: a useful clinical marker of thrombogenesis? Clin Sci. 1995;89:205–14. - PubMed
    1. Bournameaux H, Miron MJ, Blanchard J, De Moerloose P, Hoffmeyer P, Leyvraz PF. Measurement of plasma D-dimer is not useful in the prediction or detection of postoperative deep vein thrombosis in patients undergoing total knee arthroplasty. Blood Coag Fibrinol. 1998;9:749–52. - PubMed
    1. Bournameaux H, Khabiri E, Huber O, Schneider PA, Didier D, De Moerloose P, et al. Value of liquid crystal thermography and plasma D-dimer for screening of deep vein thrombosis following general abdominal surgery. Thromb Haemost. 1992;67:603–6. - PubMed
    1. Rowbotham BJ, Whitaker AN, Harrison J, Murtaugh P, Reasbeck P, Bowie EJW. Measurement of cross linked fibrin degratives in patients undergoing abdominal surgery: use in the diagnosis of postoperative venous thrombosis. Blood Coag Fibrinol. 1992;3:25–31. - PubMed