Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Mar 11;51(10):1003-10.
doi: 10.1016/j.jacc.2007.10.056.

Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation

Affiliations
Free article

Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation

Yoshihide Takahashi et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: This study sought to determine the characteristics of atrial electrograms predictive of slowing or termination of atrial fibrillation (AF) during ablation of chronic AF.

Background: There is growing recognition of a role for electrogram-based ablation.

Methods: Forty consecutive patients (34 male, 59 +/- 10 years) undergoing ablation for chronic AF persisting for a median of 12 months (range 1 to 84 months) were included. After pulmonary vein isolation and roof line ablation, electrogram-based ablation was performed in the left atrium and coronary sinus. Targeted electrograms were acquired in a 4-s window and characterized by: 1) percentage of continuous electrical activity; 2) bipolar voltage; 3) dominant frequency; 4) fractionation index; 5) mean absolute value of derivatives of electrograms; 6) local cycle length; and 7) presence of a temporal gradient of activation. Electrogram characteristics at favorable ablation regions, defined as those associated with slowing (a >or=6-ms increase in AF cycle length) or termination of AF were compared with those at unfavorable regions.

Results: The AF was terminated by electrogram-based ablation in 29 patients (73%) after targeting a total of 171 regions. Ablation at 37 (22%) of these regions was followed by AF slowing, and at 29 (17%) by AF termination. The percentage of continuous electrical activity and the presence of a temporal gradient of activation were independent predictors of favorable ablation regions (p = 0.016 and p = 0.038, respectively). Other electrogram characteristics at favorable ablation regions were not significantly different from those at unfavorable ablation regions.

Conclusions: Catheter ablation at sites displaying a greater percentage of continuous activity or a temporal activation gradient is associated with slowing or termination of chronic AF.

PubMed Disclaimer

Comment in

Publication types

Substances

LinkOut - more resources