Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2008 May;93(5):1553-62.
doi: 10.1210/jc.2008-0139. Epub 2008 Mar 11.

Accuracy of diagnostic tests for Cushing's syndrome: a systematic review and metaanalyses

Affiliations
Meta-Analysis

Accuracy of diagnostic tests for Cushing's syndrome: a systematic review and metaanalyses

Mohamed B Elamin et al. J Clin Endocrinol Metab. 2008 May.

Abstract

Context: The diagnosis of Cushing's syndrome (CS) requires the use of tests of unregulated hypercortisolism that have unclear accuracy.

Objective: Our objective was to summarize evidence on the accuracy of common tests for diagnosing CS.

Data sources: We searched electronic databases (MEDLINE, EMBASE, Web of Science, Scopus, and citation search for key articles) from 1975 through September 2007 and sought additional references from experts.

Study selection: Eligible studies reported on the accuracy of urinary free cortisol (UFC), dexamethasone suppression test (DST), and midnight cortisol assays vs. reference standard in patients suspected of CS.

Data extraction: Reviewers working in duplicate and independently extracted study characteristics and quality and data to estimate the likelihood ratio (LR) and the 95% confidence interval (CI) for each result.

Data synthesis: We found 27 eligible studies, with a high prevalence [794 (9.2%) of 8631 patients had CS] and severity of CS. The tests had similar accuracy: UFC (n = 14 studies; LR+ 10.6, CI 5.5-20.5; LR- 0.16, CI 0.08-0.33), salivary midnight cortisol (n = 4; LR+ 8.8, CI 3.5-21.8; LR- 0.07, CI 0-1.2), and the 1-mg overnight DST (n = 14; LR+ 16.4, CI 9.3-28.8; LR- 0.06, CI 0.03-0.14). Combined testing strategies (e.g. a positive result in both UFC and 1-mg overnight DST) had similar diagnostic accuracy (n = 3; LR+ 15.4, CI 0.7-358; LR- 0.11, CI 0.007-1.57).

Conclusions: Commonly used tests to diagnose CS appear highly accurate in referral practices with samples enriched with patients with CS. Their performance in usual clinical practice remains unclear.

PubMed Disclaimer

Publication types