Negative tracheal pressure during neonatal endotracheal suction
- PMID: 18344905
- DOI: 10.1203/PDR.0b013e31817289dc
Negative tracheal pressure during neonatal endotracheal suction
Abstract
Endotracheal tube (ETT) suction is the most frequently performed invasive procedure in ventilated newborn infants and is associated with adverse effects related to negative tracheal pressure. We aimed to measure suction catheter gas flow and intratracheal pressure during ETT suction of a test lung and develop a mathematical model to predict tracheal pressure from catheter and ETT dimensions and applied pressure. Tracheal pressure and catheter flow were recorded during suction of ETT sizes 2.5-4.0 mm connected to a test lung with catheters 5-8 French Gauge and applied pressures of 80-200 mm Hg. The fraction of applied pressure transmitted to the trachea was calculated for each combination, and data fitted to three nonlinear models for analysis. Tracheal pressure was directly proportional to applied pressure (r = 0.82-0.99), and catheter flow fitted a turbulent flow model (R = 0.85-0.96). With each ETT, increasing catheter size resulted in greater catheter flow (p < 0.0001) and thus lower intratracheal pressure (p < 0.0001). The fraction of applied pressure transmitted to the trachea was accurately modeled using ETT and catheter dimensions (R = 0.98-0.99). Negative tracheal pressure during in vitro ETT suction is directly proportional to applied pressure. This relationship is determined by ETT and catheter dimensions.
Similar articles
-
The effects of closed endotracheal suction on ventilation during conventional and high-frequency oscillatory ventilation.Pediatr Res. 2009 Oct;66(4):400-4. doi: 10.1203/PDR.0b013e3181b337ec. Pediatr Res. 2009. PMID: 19581839
-
Physiological responses to endotracheal and oral suctioning in paediatric patients: the influence of endotracheal tube sizes and suction pressures.Clin Intensive Care. 1991;2(6):345-50. Clin Intensive Care. 1991. PMID: 10149098
-
A bench test evaluation of a neonatal closed tracheal suction system.Pediatr Pulmonol. 1992 Jun;13(2):121-3. doi: 10.1002/ppul.1950130212. Pediatr Pulmonol. 1992. PMID: 1495856
-
Catheters for tracheal gas insufflation.Respir Care. 2001 Feb;46(2):177-84. Respir Care. 2001. PMID: 11175246 Review.
-
Closed Suction System in Tracheal Suctioning in the Critically Ill Patient Connected to Mechanical Ventilation: A Systematic Review.Arch Bronconeumol. 2024 Feb;60(2):116-118. doi: 10.1016/j.arbres.2023.11.010. Epub 2023 Nov 23. Arch Bronconeumol. 2024. PMID: 38044232 English, Spanish. No abstract available.
Cited by
-
Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography.Intensive Care Med. 2009 Dec;35(12):2130-4. doi: 10.1007/s00134-009-1663-5. Epub 2009 Sep 23. Intensive Care Med. 2009. PMID: 19774364 Free PMC article.
-
Endotracheal Suctioning of the Critically Ill Child.J Pediatr Intensive Care. 2015 Jun;4(2):56-63. doi: 10.1055/s-0035-1556747. J Pediatr Intensive Care. 2015. PMID: 31110853 Free PMC article. Review.
-
[2020 clinical practice guidelines of endotracheal suctioning in neonates with mechanical ventilation].Zhongguo Dang Dai Er Ke Za Zhi. 2020 Jun;22(6):533-542. doi: 10.7499/j.issn.1008-8830.2004168. Zhongguo Dang Dai Er Ke Za Zhi. 2020. PMID: 32571449 Free PMC article. Chinese.
-
The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume.Intensive Care Med. 2010 May;36(5):888-96. doi: 10.1007/s00134-010-1849-x. Epub 2010 Mar 16. Intensive Care Med. 2010. PMID: 20232038
-
Endotracheal suctioning in intubated newborns: an integrative literature review.Rev Bras Ter Intensiva. 2015 Jul-Sep;27(3):284-92. doi: 10.5935/0103-507X.20150048. Rev Bras Ter Intensiva. 2015. PMID: 26465249 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources