Design of dental implants, influence on the osteogenesis and fixation
- PMID: 18347951
- DOI: 10.1007/s10856-008-3421-6
Design of dental implants, influence on the osteogenesis and fixation
Abstract
The fixation and the bone ingrowth at the interface of porous cylindrical implants (total porosity of 37% and average pores diameter of 480 microm) were compared in vivo to rough cylindrical implants (R (a) = 5.3 microm), both of commercially pure titanium, made by powder metallurgy. The implants were inserted into the tibias of 20 rabbits and the animals were sacrificed 4 and 8 weeks after surgery. The percentage of bone-implant contact observed in porous implant was significantly larger than in the rough ones for all of sacrifice periods, respectively, 57% vs. 46% after 4 weeks, and 59% vs. 50% after 8 weeks. The mechanical tests showed a significant increase in the shear strength of the porous implants for the two analyzed periods, 4 and 8 weeks (14 and 20 MPa), when compared with rough ones (4 and 13 MPa). These results suggest that porous implants improve the contact at the implant-bone interface and increase the fixation to the bone, improving the osseointegration. Thus, the porous implant might be an alternative to dental implant in less favorable conditions, and appear to be better fixed to bone, offering promising alternatives.
Similar articles
-
In vivo osteogenesis and in vitro Streptococcus mutans adherence: porous-surfaced cylindrical implants vs rough-surfaced threaded implants.Int J Oral Maxillofac Implants. 2013 Nov-Dec;28(6):1630-8. doi: 10.11607/jomi.2747. Int J Oral Maxillofac Implants. 2013. PMID: 24278932
-
Implant-delivered Alendronate Causes a Dose-dependent Response on Net Bone Formation Around Porous Titanium Implants in Canines.Clin Orthop Relat Res. 2016 May;474(5):1224-33. doi: 10.1007/s11999-016-4714-6. Epub 2016 Feb 1. Clin Orthop Relat Res. 2016. PMID: 26831478 Free PMC article.
-
Evaluation of bone ingrowth into porous titanium implant: histomorphometric analysis in rabbits.Braz Oral Res. 2010 Oct-Dec;24(4):399-405. doi: 10.1590/s1806-83242010000400005. Braz Oral Res. 2010. PMID: 21180959
-
Peri-implant osteogenesis in health and osteoporosis.Micron. 2005;36(7-8):630-44. doi: 10.1016/j.micron.2005.07.008. Epub 2005 Sep 6. Micron. 2005. PMID: 16182543 Review.
-
Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions.Periodontol 2000. 2017 Feb;73(1):22-40. doi: 10.1111/prd.12179. Periodontol 2000. 2017. PMID: 28000277 Review.
Cited by
-
Electrospun Poly(butylene-adipate-co-terephthalate)/Nano-hyDroxyapatite/Graphene Nanoribbon Scaffolds Improved the In Vivo Osteogenesis of the Neoformed Bone.J Funct Biomater. 2021 Feb 5;12(1):11. doi: 10.3390/jfb12010011. J Funct Biomater. 2021. PMID: 33562592 Free PMC article.
-
Novel production method of porous surface Ti samples for biomedical application.J Mater Sci Mater Med. 2012 Feb;23(2):357-64. doi: 10.1007/s10856-011-4515-0. Epub 2011 Dec 20. J Mater Sci Mater Med. 2012. PMID: 22183791
-
Titanium scaffold osteogenesis in healthy and osteoporotic rats is improved by the use of low-level laser therapy (GaAlAs).Lasers Med Sci. 2016 Jul;31(5):899-905. doi: 10.1007/s10103-016-1930-y. Epub 2016 Apr 7. Lasers Med Sci. 2016. PMID: 27056701
-
Effect of low-level mechanical vibration on osteogenesis and osseointegration of porous titanium implants in the repair of long bone defects.Sci Rep. 2015 Nov 25;5:17134. doi: 10.1038/srep17134. Sci Rep. 2015. PMID: 26601709 Free PMC article.
-
Calibration of Aseptic Loosening Simulation for Coatings Osteoinductive Effect.Ann Biomed Eng. 2025 Jan;53(1):34-47. doi: 10.1007/s10439-024-03588-9. Epub 2024 Aug 9. Ann Biomed Eng. 2025. PMID: 39120770 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources