Fracture strength and fatigue resistance of all-ceramic molar crowns manufactured with CAD/CAM technology
- PMID: 18355164
- DOI: 10.1111/j.1532-849X.2008.00305.x
Fracture strength and fatigue resistance of all-ceramic molar crowns manufactured with CAD/CAM technology
Abstract
Purpose: All-ceramic crowns are subject to fracture during function, especially in the posterior area. The use of yttrium-stabilized zirconium-oxide ceramic as a substructure for all-ceramic crowns to improve fracture resistance is unproven. The aim of this study was to compare fracture strength and fatigue resistance of new zirconium-oxide and feldspathic all-ceramic crowns made with computer-aided design/computer-aided manufacturing (CAD/CAM).
Materials and methods: An ivorine molar was prepared to receive an all-ceramic crown. Using epoxy resin, 40 replication dies were made of the prepared tooth. Twenty feldspathic all-ceramic crowns (Vita Mark II) (VMII) and 20 zirconium-oxide crown copings (In-Ceram YZ) (YZ) were made using CAD/CAM technique (CEREC-3D). The YZ copings were sintered and veneered manually with a fine-particle ceramic (VM9). All crowns were cemented to their respective dies using resin cement (Panavia F 2.0). Ten crowns in each group were subjected to compressive fatigue loading in a universal testing machine (instron). The other ten crowns from each group were loaded to fracture at a crosshead speed of 1 mm/min. Data were statistically analyzed using independent t-test and Fisher's exact test at alpha= 0.05.
Results: There was a significant difference between the survival rates of the two materials during the fatigue test (p < 0.001). All VMII crowns survived without any crack formation, while all YZ crowns fractured (40%) or developed cracks (60%). All the YZ crown fractures occurred within the veneering layer during the fatigue test. There was no significant difference in mean fracture load between the two materials (p= 0.268). Mean fracture loads (standard deviation) in N were: 1459 (492) for YZ crowns and 1272 (109) for VMII crowns.
Conclusions: The performance of VMII crowns was superior to YZ crowns in the fatigue test. The premature fractures and cracks of the YZ crowns were attributed to weakness in the YZ veneer layer or in the core/veneer bond.
Similar articles
-
Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns.J Prosthet Dent. 2006 Feb;95(2):117-23. doi: 10.1016/j.prosdent.2005.11.014. J Prosthet Dent. 2006. PMID: 16473085
-
Strength of CAD/CAM-generated esthetic ceramic molar implant crowns.Int J Oral Maxillofac Implants. 2008 Jul-Aug;23(4):609-17. Int J Oral Maxillofac Implants. 2008. PMID: 18807555
-
Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns.J Prosthodont. 2012 Jan;21(1):28-32. doi: 10.1111/j.1532-849X.2011.00773.x. Epub 2011 Oct 18. J Prosthodont. 2012. PMID: 22008462
-
All-ceramic restorations: classification and clinical evaluations.Compend Contin Educ Dent. 1999 Dec;20(12):1115-24, 1126 passim; quiz 1136. Compend Contin Educ Dent. 1999. PMID: 10850265 Review.
-
Combining monolithic zirconia crowns, digital impressioning, and regenerative cement for a predictable restorative alternative to PFM.Compend Contin Educ Dent. 2013 Mar;34(3):212-22. Compend Contin Educ Dent. 2013. PMID: 23931266 Review.
Cited by
-
Surface Characterization of Electro-Assisted Titanium Implants: A Multi-Technique Approach.Materials (Basel). 2020 Feb 5;13(3):705. doi: 10.3390/ma13030705. Materials (Basel). 2020. PMID: 32033256 Free PMC article. Review.
-
Effect of three different veneering techniques on the stress distribution and in vitro fatigue behavior of core-veneer all-ceramic fixed partial dentures.J Dent Res Dent Clin Dent Prospects. 2021 Summer;15(3):188-196. doi: 10.34172/joddd.2021.032. Epub 2021 Aug 25. J Dent Res Dent Clin Dent Prospects. 2021. PMID: 34712410 Free PMC article.
-
Laboratory simulation of Y-TZP all-ceramic crown clinical failures.J Dent Res. 2009 Apr;88(4):382-6. doi: 10.1177/0022034509333968. J Dent Res. 2009. PMID: 19407162 Free PMC article.
-
Effect of thermomechanical aging on fracture strength of anterior crowns fabricated with different CAD-CAM materials.J Adv Prosthodont. 2025 Jun;17(3):158-168. doi: 10.4047/jap.2025.17.3.158. Epub 2025 Jun 25. J Adv Prosthodont. 2025. PMID: 40687195 Free PMC article.
-
Repair bond strengths of non-aged and aged resin nanoceramics.J Adv Prosthodont. 2017 Oct;9(5):364-370. doi: 10.4047/jap.2017.9.5.364. Epub 2017 Oct 16. J Adv Prosthodont. 2017. PMID: 29142644 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous