An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations

Affiliations
Comparative Study

An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations

Philip L Tan et al. J Prosthodont. 2008 Jul.

Abstract

Purpose: To determine if there was a significant difference between the vertical marginal openings of cast restorations, computer-aided design, and computer-aided machining restorations.

Materials and methods: Ten working dies were created from a single master die and used to fabricate ten restorations in each of the following groups: computer-aided design/computer-assisted machining (CAD/CAM), WAX/CAM, and WAX/CAST. The CAD/CAM titanium restorations were fabricated using the scanning and crown design modules of the KaVo Everest system. The WAX/CAM titanium restorations were fabricated using the double scan technique with the KaVo Everest system. The WAX/CAST high noble copings were fabricated using the conventional lost wax casting technique. The restorations were seated on the master die, and high-resolution digital photographs were made of the marginal area on all four sides. The vertical marginal opening was then measured using a calibrated digital software program. One-way ANOVA and Tukey's post hoc tests were used to determine the presence of statistically significant differences.

Results: The vertical margin openings were CAD/CAM: 79.43 +/- 25.46 microm; WAX/CAM: 73.12 +/- 24.15 microm; WAX/CAST: 23.91 +/- 9.80 microm. There was a statistically significant difference between the WAX/CAST group and the remaining groups.

Conclusions: There was no difference between the vertical marginal gaps of the CAD/CAM and WAX/CAM. The WAX/CAST technique resulted in smaller vertical marginal gaps than either CAD/CAM or WAX/CAM.