Equivalent performance of epicardial versus endocardial permanent pacing in children: a single institution and manufacturer experience
- PMID: 18355537
- DOI: 10.1016/j.athoracsur.2007.12.075
Equivalent performance of epicardial versus endocardial permanent pacing in children: a single institution and manufacturer experience
Abstract
Background: Children requiring permanent pacing have a lifelong need for follow-up. Epicardial leads have traditionally fared worse than endocardial counterparts. We tested the hypothesis that steroid-eluting epicardial and endocardial leads had equivalent outcomes.
Methods: We reviewed medical records of 148 children, mean age 8.2 +/- 4.8 years, in whom a dual-chamber pacemaker system with steroid-eluting leads from a single manufacturer was implanted. Primary outcome was mortality. Secondary outcomes included freedom from lead failure and pacemaker system reintervention. Loss of capture-sensing, lead displacement-fracture, exit block, and high thresholds constituted lead failure. Reintervention included need for lead revision or generator change.
Results: There was no early mortality. Late mortality occurred once (0.5 +/- 0.5 deaths/1,000 patient-months) and eight times (3.4 +/- 1.2 deaths/1,000 patient-months) in the endocardial and epicardial groups, respectively. The relative hazard of endocardial versus epicardial site for lead failure was 0.408 (p = 0.038) and for reintervention was 0.629 (p = 0.002). Endocardial and epicardial groups differed in important ways: concomitant cardiac surgery 5% (3 of 61) versus 27% (27 of 99); congenital heart disease 33% (20 of 61) versus 90% (89 of 99); single ventricle physiology 13% (8 of 61) versus 52% (51/99); and age (10.5 +/- 4.5 years vs 5.5 +/- 5.2 years). Adjusting for these covariants, the relative hazard for freedom from lead failure for endocardial versus epicardial leads was 0.546 (p = 0.360). The adjusted relative hazard for freedom from reintervention was 0.157 (p = 0.045).
Conclusions: Technologic advances attenuate important differences in lead failure rates between endocardial and epicardial steroid-eluting pacing leads and thus bridge the performance gap between these fixation modes.
Similar articles
-
Predictors affecting durability of epicardial pacemaker leads in pediatric patients.J Thorac Cardiovasc Surg. 2008 Feb;135(2):361-6. doi: 10.1016/j.jtcvs.2007.09.002. J Thorac Cardiovasc Surg. 2008. PMID: 18242269
-
Permanent epicardial pacing in pediatric patients: 12-year experience at a single center.Ann Thorac Surg. 2012 Feb;93(2):634-9. doi: 10.1016/j.athoracsur.2011.09.072. Epub 2011 Dec 21. Ann Thorac Surg. 2012. PMID: 22192754
-
Twenty years of paediatric cardiac pacing: 515 pacemakers and 480 leads implanted in 292 patients.Europace. 2006 Jul;8(7):530-6. doi: 10.1093/europace/eul062. Europace. 2006. PMID: 16798767
-
Efficacy of prophylactic epicardial pacing leads in children and young adults.Ann Thorac Surg. 2004 Jul;78(1):197-202; discussion 202-3. doi: 10.1016/j.athoracsur.2004.02.008. Ann Thorac Surg. 2004. PMID: 15223427 Review.
-
Pacemaker and implantable cardioverter defibrillator implantation in pediatric patients.Minerva Cardioangiol. 2007 Dec;55(6):803-13. Minerva Cardioangiol. 2007. PMID: 18091647 Review.
Cited by
-
The use of laser lead extraction sheath in the presence of supra-cardiac occlusion of the central veins for cardiac implantable electronic device lead upgrade or revision.PLoS One. 2021 May 14;16(5):e0251829. doi: 10.1371/journal.pone.0251829. eCollection 2021. PLoS One. 2021. PMID: 33989335 Free PMC article.
-
Arrhythmias in structural heart disease.Curr Cardiol Rep. 2014 Aug;16(8):510. doi: 10.1007/s11886-014-0510-7. Curr Cardiol Rep. 2014. PMID: 24950672 Review.
-
Pacing device therapy in infants and children: a review.J Artif Organs. 2013 Mar;16(1):23-33. doi: 10.1007/s10047-012-0668-y. Epub 2012 Oct 27. J Artif Organs. 2013. PMID: 23104398 Review.
-
Epicardial Versus Endocardial Pacing in Paediatric Patients with Atrioventricular Block or Sinus Node Dysfunction: A Systematic Review and Meta-analysis.Pediatr Cardiol. 2023 Dec;44(8):1641-1648. doi: 10.1007/s00246-023-03213-x. Epub 2023 Jul 22. Pediatr Cardiol. 2023. PMID: 37480376 Free PMC article.
-
Transvenous pacing leads implanted in epicardial position: A recipe for future epicardial pacing electrode?JTCVS Tech. 2025 May 28;32:144-151. doi: 10.1016/j.xjtc.2025.05.011. eCollection 2025 Aug. JTCVS Tech. 2025. PMID: 40814659 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous