Comparative Study
. 2008 Apr;5(4):526-35.
doi: 10.1016/j.hrthm.2008.01.008. Epub 2008 Jan 17.

Image integration using NavX Fusion: initial experience and validation

Affiliations
Comparative Study

Image integration using NavX Fusion: initial experience and validation

Anthony G Brooks et al. Heart Rhythm. 2008 Apr.

Abstract

Background: Three-dimensional virtual anatomic navigation is increasingly used during mapping and ablation of complex arrhythmias. NavX Fusion software aims to mold the virtual anatomy to the patient's computed tomography (CT) image; however, the accuracy and clinical usefulness of this system have not been reported.

Objective: The purpose of this study was to assess the accuracy and describe the initial experience of CT image integration using NavX Fusion for atrial fibrillation ablation.

Methods: This study consisted of 55 consecutive patients undergoing atrial fibrillation ablation using NavX Fusion navigation. Left atrial NavX geometries were compared to a corresponding CT for geometric match. Geometric match, expressed as the difference in millimeters between CT and NavX geometry, was calculated for the original geometry (GEO-1), field scaled and primary fused geometry (GEO-2), and final secondary fused geometry (GEO-3). Navigational accuracy was assessed by moving the catheter to 10 discrete anatomic sites and determining the distance between the catheter tip and the closest GEO-2, GEO-3, and CT surface. Fusion integration time and procedural and fluoroscopic durations were recorded to assess clinical usefulness.

Results: GEO-1, GEO-2 and GEO-3 were associated with CT-GEO errors of 6.6+/-2.8 mm, 4.1+/-0.7 mm, 1.9+/-0.4 mm, respectively. Navigational accuracy was not significantly different for GEO-2, GEO-3, and CT at 3.4+/-1.6 mm to any surface. A significant (P < or =.001) inverse curvilinear relationship was present between case number and the time required for image integration (r(2) = 0.35) and the fluoroscopic time normalized for procedural duration (r(2) = 0.18).

Conclusion: Image integration using the NavX Fusion software is highly accurate and is associated with a progressive reduction in fluoroscopic time relative to procedural duration.