Laboratory evaluation and field application of roadside oral fluid collectors and drug testing devices
- PMID: 18367979
- DOI: 10.1097/FTD.0b013e3181679249
Laboratory evaluation and field application of roadside oral fluid collectors and drug testing devices
Abstract
This study was a part of a collaborative U.S./E.U. international research effort (Roadside Testing Assessment, ROSITA II) to assess illegal drug use among motor vehicle operators suspected of driving while under the influence of drugs and to evaluate the effectiveness of point-of-collection oral fluid drug detection technologies. A goal of the study was to assess commercial oral fluid drug testing devices for potential use in law enforcement. Ten devices were evaluated in the laboratory for their ability to meet manufacturers' claimed (and proposed) cutoff concentrations for the detection of amphetamine(s), cocaine/metabolite, opiates, cannabinoids, and benzodiazepines (2 devices). The field study portion of the research was conducted in major cities in the United States and Western Europe by teams of scientists working in collaboration with the local police. In Salt Lake City, Utah, the Drugwipe, Securetec, Ottobrunn, Germany (Securetec) oral fluids drug testing device was also evaluated in the field by testing suspected drug-impaired drivers. During the initial phase of the field study, 40 subjects were recruited. Drugwipe results were compared with laboratory-based immunoassay and mass spectrometry results and demonstrated that calculated sensitivities were between 75% and 100% depending on drug class. Specificities varied from 36% for cannabinoids to over 95% for opiates. During the second phase of the field study, 267 subjects were recruited. The Drugwipe sensitivities were 36.4%, 35.9%, 42.9%, and 7.7%, respectively, for amphetamine(s), cocaine, opiates, and cannabinoids. The Drugwipe specificities were 99.2%, 97.4%, 99.6%, and 99.6%, respectively, for amphetamine(s), cocaine, opiates, and cannabinoids. Drugwipe failed to meet the study criteria for acceptable device performance, required performance sensitivities, and specificities 90% or greater.
Similar articles
-
Roadside oral fluid testing: comparison of the results of drugwipe 5 and drugwipe benzodiazepines on-site tests with laboratory confirmation results of oral fluid and whole blood.Forensic Sci Int. 2008 Mar 5;175(2-3):140-8. doi: 10.1016/j.forsciint.2007.05.022. Epub 2007 Jul 20. Forensic Sci Int. 2008. PMID: 17640837
-
Evaluation of on-site oral fluid screening using Drugwipe-5(+), RapidSTAT and Drug Test 5000 for the detection of drugs of abuse in drivers.Forensic Sci Int. 2010 May 20;198(1-3):2-6. doi: 10.1016/j.forsciint.2009.10.012. Epub 2009 Nov 12. Forensic Sci Int. 2010. PMID: 19913376
-
Performance evaluation of on-site oral fluid drug screening devices in normal police procedure in Germany.Forensic Sci Int. 2014 May;238:120-4. doi: 10.1016/j.forsciint.2014.02.005. Epub 2014 Feb 18. Forensic Sci Int. 2014. PMID: 24699311
-
Analytical techniques for drug detection in oral fluid.Ther Drug Monit. 2008 Apr;30(2):181-7. doi: 10.1097/FTD.0b013e3181685088. Ther Drug Monit. 2008. PMID: 18367978 Review.
-
Current developments in drug testing in oral fluid.Ther Drug Monit. 2008 Apr;30(2):196-202. doi: 10.1097/FTD.0b013e318167d563. Ther Drug Monit. 2008. PMID: 18367980 Review.
Cited by
-
Screening, brief intervention, and referral to treatment (SBIRT) for offenders: protocol for a pragmatic randomized trial.Addict Sci Clin Pract. 2013 Oct 23;8(1):16. doi: 10.1186/1940-0640-8-16. Addict Sci Clin Pract. 2013. PMID: 24499609 Free PMC article. Clinical Trial.
-
A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context.J Anal Methods Chem. 2016;2016:1234581. doi: 10.1155/2016/1234581. Epub 2016 Aug 17. J Anal Methods Chem. 2016. PMID: 27610266 Free PMC article.
-
Oral fluid testing for drugs of abuse.Clin Chem. 2009 Nov;55(11):1910-31. doi: 10.1373/clinchem.2008.108670. Epub 2009 Sep 10. Clin Chem. 2009. PMID: 19745062 Free PMC article. Review.
-
Cannabinoids in oral fluid by on-site immunoassay and by GC-MS using two different oral fluid collection devices.Anal Bioanal Chem. 2014 Jul;406(17):4117-28. doi: 10.1007/s00216-014-7813-9. Epub 2014 May 15. Anal Bioanal Chem. 2014. PMID: 24828976 Free PMC article.
-
Roadside Drug Testing Approaches.Molecules. 2021 May 29;26(11):3291. doi: 10.3390/molecules26113291. Molecules. 2021. PMID: 34072538 Free PMC article. Review.
Publication types