Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Mar 15;75(1):284-93.
doi: 10.1016/j.talanta.2007.11.031. Epub 2007 Nov 19.

Comparison of four extraction methods for the analysis of 24 pesticides in soil samples with gas chromatography-mass spectrometry and liquid chromatography-ion trap-mass spectrometry

Affiliations
Comparative Study

Comparison of four extraction methods for the analysis of 24 pesticides in soil samples with gas chromatography-mass spectrometry and liquid chromatography-ion trap-mass spectrometry

C Lesueur et al. Talanta. .

Abstract

With a view to analyse multiresidues of pesticides in soil samples, a new ultrasonic solvent extraction (USE) was compared to the European Norm DIN 12393 for foodstuff (extraction with acetone, partitioning with ethylacetate/cyclohexane and clean-up with gel permeation chromatography (GPC)), the QuECheRS method and a pressurised liquid extraction (PLE) method. Pesticides were analysed with both GC-MS and HPLC-MS/MS. The reference materials were the EUROSOIL 7 and its subsoil SO26 as well as a sea sand. All the substances were observed to be linear in the range of 4-800 ng g(-1) for the European Norm DIN 12393, 7-1400 ng g(-1) for the USE method and 20-4000 ng g(-1) for the QueCheRS and the PLE methods. Limits of detection (LOD) and limits of quantification (LOQ) were with HPLC between 0.006 and 0.23 ng g(-1) and between 0.022 and 0.77 ng g(-1), respectively, with the exception of diuron (LOD up to 11.8 ng g(-1); LOQ up to 39.2 ng g(-1)). With GC they ranged from 3.0 to 87.5 ng g(-1) and from 10 to 292 ng g(-1), respectively. All substances could be recovered with USE as well as with the QuECheRS method; the European Norm DIN 12393 could not recover carbendazim and metamitron; the PLE carbendazim, metamitron and monolinuron. For the remaining substances, recoveries at a 500 ng g(-1) fortification level ranged from 10.9 to 96.3% with the USE. In comparison, the QuECheRS method was the most efficient extraction method with recoveries from 27.3 to 120.9%. It was followed by the European Norm DIN 12393 with recoveries between 6.8 and 108.1% and the PLE with recoveries from 12.2 to 153.2%. Recoveries were higher from the EUROSOIL 7 than from the SO 26. The repeatability expressed in term of standard deviation was below 20% for all substances and all materials.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources