Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2008 Apr;31(4):409-17.
doi: 10.1111/j.1540-8159.2008.01009.x.

Full-motion two- and three-dimensional pulmonary vein imaging by intracardiac echocardiography after pulmonary vein isolation

Affiliations
Clinical Trial

Full-motion two- and three-dimensional pulmonary vein imaging by intracardiac echocardiography after pulmonary vein isolation

Yasuo Okumura et al. Pacing Clin Electrophysiol. 2008 Apr.

Abstract

Background: The pulmonary veins (PVs) are topographically complex and motile, so angiographic visualization of the PVs anatomy is limited. An imaging technique that accurately portrays the pulmonary vein (PV) anatomy would be valuable during and after catheter ablation procedures.

Purpose: We investigated whether three-dimensional (3D) intracardiac echocardiography (ICE) can visualize radiofrequency (RF)-induced tissue changes after PV isolation.

Methods: We performed 3D ICE studies with a 9F, 9-MHz ICE catheter after segmental or extended PV isolation. The ICE catheter was placed 3-4 cm inside the PV ostium and mounted onto a pullback device. Sequential two-dimensional (2D) images of the full length of the vein were obtained in 0.3 mm steps with cardiac and respiratory cycle gating. Each image was fed into a computer, and the aggregate data set was reconstructed into a 3D, full-motion image. RF lesion location and lesion size were studied on 67 pullback images from 29 patients.

Results: The 2D and 3D reconstruction was possible for 27 left superior PVs, 13 left inferior PVs, 26 right superior PVs, and one right inferior PV. The ablation site was identified 3-7 mm inside the PV ostium, and a 1/2 - 4/5 circumferential area was ablated with no clinically relevant stenosis. No significant differences were found on the ablated area or ablation site between segmental and extensive PV isolation.

Conclusion: The 2D and 3D ICE of the PVs provides detailed anatomical information of the proximal PVs, and RF-induced tissue changes in the PV wall can be visualized by ICE.

PubMed Disclaimer

Similar articles

Publication types