Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 May:86 Suppl 1:5-28.
doi: 10.1111/j.1755-3768.2008.01234.x.

Assessment and statistics of surgically induced astigmatism

Affiliations
Free article

Assessment and statistics of surgically induced astigmatism

Kristian Naeser. Acta Ophthalmol. 2008 May.
Free article

Abstract

The aim of the thesis was to develop methods for assessment of surgically induced astigmatism (SIA) in individual eyes, and in groups of eyes. The thesis is based on 12 peer-reviewed publications, published over a period of 16 years. In these publications older and contemporary literature was reviewed(1). A new method (the polar system) for analysis of SIA was developed. Multivariate statistical analysis of refractive data was described(2-4). Clinical validation studies were performed. The description of a cylinder surface with polar values and differential geometry was compared. The main results were: refractive data in the form of sphere, cylinder and axis may define an individual patient or data set, but are unsuited for mathematical and statistical analyses(1). The polar value system converts net astigmatisms to orthonormal components in dioptric space. A polar value is the difference in meridional power between two orthogonal meridians(5,6). Any pair of polar values, separated by an arch of 45 degrees, characterizes a net astigmatism completely(7). The two polar values represent the net curvital and net torsional power over the chosen meridian(8). The spherical component is described by the spherical equivalent power. Several clinical studies demonstrated the efficiency of multivariate statistical analysis of refractive data(4,9-11). Polar values and formal differential geometry describe astigmatic surfaces with similar concepts and mathematical functions(8). Other contemporary methods, such as Long's power matrix, Holladay's and Alpins' methods, Zernike(12) and Fourier analyses(8), are correlated to the polar value system. In conclusion, analysis of SIA should be performed with polar values or other contemporary component systems. The study was supported by Statens Sundhedsvidenskabeligt Forskningsråd, Cykelhandler P. Th. Rasmussen og Hustrus Mindelegat, Hotelejer Carl Larsen og Hustru Nicoline Larsens Mindelegat, Landsforeningen til Vaern om Synet, Forskningsinitiativet for Arhus Amt, Alcon Denmark, and Desirée and Niels Ydes Fond.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources