Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Apr;14(2):213-21.
doi: 10.1016/j.math.2008.02.004. Epub 2008 Mar 25.

Inter- and intra-examiner reliability of single and composites of selected motion palpation and pain provocation tests for sacroiliac joint

Affiliations

Inter- and intra-examiner reliability of single and composites of selected motion palpation and pain provocation tests for sacroiliac joint

Amir Massoud Arab et al. Man Ther. 2009 Apr.

Abstract

The sacroiliac joint (SIJ) has been implicated as a potential source of low back and buttock pain. Several types of motion palpation and provocation tests are used to examine the SIJ. It has been suggested that use of a cluster of motion palpation or provocation tests is a more acceptable method than single test to assess SIJ. This study examined the inter- and intra-examiner reliability of single and composites of the motion palpation and provocation tests together. Twenty-five patients between the ages of 20 and 65 years participated. Four motion palpation and three provocation tests were examined three times on both sides (left, right) by two examiners. Kappa coefficient and prevalence-adjusted and bias-adjusted kappa (PABAK) were calculated to evaluate the reliability. PABAK for intra- and inter-examiner reliability of individual tests ranged from 0.36 to 0.84 (95% CI: -0.22 to 1.12) and 0.52 to 0.84 (95% CI: -0.18 to 1.08) which is considered fair to substantial. PABAK for intra- and inter-examiner reliability for clusters of motion palpation or provocation tests ranged from 0.44 to 0.92 (95% CI: -0.36 to 1.2) which is considered moderate to excellent reliability. PABAK for intra- and inter-examiner reliability of composites of motion palpation and provocation tests ranged from 0.44 to 1.00 (95% CI: -0.22 to 1.12) and 0.52 to 0.92 (95% CI: -0.02 to 1.32) which is considered substantial to excellent. It seems that composites of motion palpation and provocation tests together have reliability sufficiently high for use in clinical assessment of the SIJ.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources