Multipixel system for gigahertz frequency-domain optical imaging of finger joints
- PMID: 18377031
- DOI: 10.1063/1.2840344
Multipixel system for gigahertz frequency-domain optical imaging of finger joints
Abstract
Frequency-domain optical imaging systems have shown great promise for characterizing blood oxygenation, hemodynamics, and other physiological parameters in human and animal tissues. However, most of the frequency domain systems presented so far operate with source modulation frequencies below 150 MHz. At these low frequencies, their ability to provide accurate data for small tissue geometries such as encountered in imaging of finger joints or rodents is limited. Here, we present a new system that can provide data up to 1 GHz using an intensity modulated charged coupled device camera. After data processing, the images show the two-dimensional distribution of amplitude and phase of the light modulation on the finger surface. The system performance was investigated and test measurements on optical tissue phantoms were taken to investigate whether higher frequencies yield better signal-to-noise ratios (SNRs). It could be shown that local changes in optical tissue properties, as they appear in the initial stages of rheumatoid arthritis in a finger joint, are detectable by simple image evaluation, with the range of modulation frequency around 500 MHz proving to yield the highest SNR.
Similar articles
-
Experimental evidence of the theoretical spatial frequency response of cubic phase mask wavefront coding imaging systems.Opt Express. 2012 Jan 16;20(2):1878-95. doi: 10.1364/OE.20.001878. Opt Express. 2012. PMID: 22274533
-
Imaging and detection technologies for image analysis in electrophoresis.Electrophoresis. 2001 Mar;22(5):801-13. doi: 10.1002/1522-2683()22:5<801::AID-ELPS801>3.0.CO;2-X. Electrophoresis. 2001. PMID: 11332747 Review.
-
Sagittal laser optical tomography for imaging of rheumatoid finger joints.Phys Med Biol. 2004 Apr 7;49(7):1147-63. doi: 10.1088/0031-9155/49/7/005. Phys Med Biol. 2004. PMID: 15128195
-
[New laser equipment to improve diagnosis and follow-up. What can the new rheumatoid scanner do? (interview by Dr. Thomas Meissner)].MMW Fortschr Med. 2003 Jan 16;145(1-2):16. MMW Fortschr Med. 2003. PMID: 12638433 German. No abstract available.
-
Multipixel techniques for frequency-domain photon migration imaging.Biotechnol Prog. 1997 Sep-Oct;13(5):669-80. doi: 10.1021/bp970085g. Biotechnol Prog. 1997. PMID: 9336987 Review.
Cited by
-
Effect of noise on modulation amplitude and phase in frequency-domain diffusive imaging.J Biomed Opt. 2012 Jan;17(1):016010. doi: 10.1117/1.JBO.17.1.016010. J Biomed Opt. 2012. PMID: 22352660 Free PMC article.
-
Feasibility of Direct Digital Sampling for Diffuse Optical Frequency Domain Spectroscopy in Tissue.Meas Sci Technol. 2013 Apr 1;24(4):045501. doi: 10.1088/0957-0233/24/4/045501. Meas Sci Technol. 2013. PMID: 24678143 Free PMC article.
-
Non-contact small animal fluorescence imaging system for simultaneous multi-directional angular-dependent data acquisition.Biomed Opt Express. 2014 Jun 18;5(7):2301-16. doi: 10.1364/BOE.5.002301. eCollection 2014 Jul 1. Biomed Opt Express. 2014. PMID: 25071965 Free PMC article.
-
Development of an optical imaging platform for functional imaging of small animals using wide-field excitation.Biomed Opt Express. 2010 Jul 15;1(1):143-156. doi: 10.1364/BOE.1.000143. Biomed Opt Express. 2010. PMID: 21258454 Free PMC article.
-
Diffuse optical imaging using spatially and temporally modulated light.J Biomed Opt. 2012 Jul;17(7):071311. doi: 10.1117/1.JBO.17.7.071311. J Biomed Opt. 2012. PMID: 22894472 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical