Cy5 labeled antimicrobial peptides for enhanced detection of Escherichia coli O157:H7
- PMID: 18378438
- DOI: 10.1016/j.bios.2008.02.005
Cy5 labeled antimicrobial peptides for enhanced detection of Escherichia coli O157:H7
Abstract
Fluorescently labeled antimicrobial peptides were evaluated as a potential replacement of labeled antibodies in a sandwich assay for the detection of Escherichia coli O157:H7. Antimicrobial peptides naturally bind to the lipopolysaccharide component of bacterial cell walls as part of their mode of action. Because of their small size relative to antibodies peptides can bind to cell surfaces with greater density, thereby increasing the optical signal and improving sensitivity. This method combines the specificity of a capture antibody with the increased sensitivity provided by using a labeled peptide as a detection molecule. The antimicrobial peptides cecropin P1, SMAP29, and PGQ were labeled with the fluorescent dye Cy5 via maleimide linker chemistry. Preliminary screening using a whole-cell solution binding assay revealed that Cy5 cecropin P1 enhanced the detection of E. coli O157:H7 relative to a Cy5 labeled anti-E. coli O157:H7 antibody 10-fold. Detection sensitivity of antibody and peptide were also compared with a prototype immuno-magnetic bead biosensor. Detection using Cy5 cecropin P1 resulted in a 10-fold improvement in sensitivity. Correlation of peptide antimicrobial activity with detection of E. coli O157:H7 indicated that activity was not predictive of the sensitivity of the fluorescent assay.
Similar articles
-
Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples.Biosens Bioelectron. 2007 May 15;22(11):2408-14. doi: 10.1016/j.bios.2006.08.030. Epub 2006 Oct 12. Biosens Bioelectron. 2007. PMID: 17045791
-
Quantum dot biolabeling coupled with immunomagnetic separation for detection of Escherichia coli O157:H7.Anal Chem. 2004 Aug 15;76(16):4806-10. doi: 10.1021/ac049442+. Anal Chem. 2004. PMID: 15307792
-
Antibody microarray detection of Escherichia coli O157:H7: Quantification, assay limitations, and capture efficiency.Anal Chem. 2006 Sep 15;78(18):6601-7. doi: 10.1021/ac0608467. Anal Chem. 2006. PMID: 16970339
-
Characterisation of Escherichia coli O157 strains from humans, cattle and pigs in the North-West Province, South Africa.Int J Food Microbiol. 2008 Dec 10;128(2):181-8. doi: 10.1016/j.ijfoodmicro.2008.08.011. Epub 2008 Aug 28. Int J Food Microbiol. 2008. PMID: 18848733 Review.
-
Escherichia coli O157:H7 colonization in small domestic ruminants.FEMS Microbiol Rev. 2009 Mar;33(2):394-410. doi: 10.1111/j.1574-6976.2008.00138.x. Epub 2008 Dec 12. FEMS Microbiol Rev. 2009. PMID: 19207740 Review.
Cited by
-
Bacteria-targeting BSA-stabilized SiC nanoparticles as a fluorescent nanoprobe for forensic identification of saliva.Mikrochim Acta. 2019 Nov 9;186(12):756. doi: 10.1007/s00604-019-3890-y. Mikrochim Acta. 2019. PMID: 31707552
-
Application of immobilized synthetic anti-lipopolysaccharide peptides for the isolation and detection of bacteria.Eur J Clin Microbiol Infect Dis. 2015 Aug;34(8):1639-45. doi: 10.1007/s10096-015-2399-5. Epub 2015 May 19. Eur J Clin Microbiol Infect Dis. 2015. PMID: 25987244
-
Electrochemical Peptide-Based Sensors for Foodborne Pathogens Detection.Molecules. 2021 May 27;26(11):3200. doi: 10.3390/molecules26113200. Molecules. 2021. PMID: 34071841 Free PMC article. Review.
-
Recent Advances on Peptide-Based Biosensors and Electronic Noses for Foodborne Pathogen Detection.Biosensors (Basel). 2023 Feb 11;13(2):258. doi: 10.3390/bios13020258. Biosensors (Basel). 2023. PMID: 36832024 Free PMC article. Review.
-
Antimicrobial Peptides as Probes in Biosensors Detecting Whole Bacteria: A Review.Molecules. 2020 Apr 24;25(8):1998. doi: 10.3390/molecules25081998. Molecules. 2020. PMID: 32344585 Free PMC article. Review.